Vaillant VRT 392f Bedienungsanleitung

Seite von 36
Operating manual VRT 392f 0020044239_01
16
h
 Note  
The same procedure as shown in the example 
for heating circuit applies when inputting the 
time programme for hot water generation or for 
a circulation pump. A comfort temperature does 
not need to be entered for hot water 
generation and the circulation pump.
4.7.2  Programming holiday periods
For a longer period of time when you are not at home, 
you can define a lower room temperature. This will save 
heating energy. The VRT 392f ensures that the 
living spaces are only heated with reference to the 
specified temperature.
You can specify a room target temperature of 15 °C 
if you wish to go on holiday from 10 - 24 February. The 
living rooms are only heated up to 15 °C during this 
period.
Holiday times can be set as follows:
 
Turn the left-hand dial until you reach screen   7 
"Holiday programming for whole system".
Holiday programming
for whole system
 7
Period 
 10. 02. 06 - 
.
 
Room value:
   10 °C
> set start day
Fig. 4.14  Screen   7 (example)
 
Turn the right-hand dial until the cursor   is 
positioned in front of the start date. 
The field shows the text "Set starting day".
 
Click the right-hand dial.
The field is highlighted.
 
Turn the right-hand dial until the desired start day 
is displayed.
 
Click the right-hand dial.
The day date is set. The display changes from inverse 
back to normal.
 
Set the month and year of the start date in the 
same way.
In the display field for explanation the text "Set starting 
month“ or "Set starting year" appears.
 
Set the end date of the holiday period in the same 
way.
Enter the room temperature as follows:
 
Turn the right-hand dial until the cursor   is 
positioned in front of the room target temperature 
input field.
The explanation text "Select room temperature" 
appears.
 
Click the right-hand dial.
The field is highlighted.
 
Turn the right-hand dial until the desired value is 
displayed (values from 5 °C to 30 °C in half degree 
steps are possible).
 
Click the right-hand dial.
The desired room set target temperature is set. The 
display changes from inverse back to normal.
4.7.3  Heating settings
Here you can enter the set-back temperature. The 
heating is controlled with reference to this temperature 
outside the specified time window.
HC1
Parameter
 8
Night set back temperature
15 . 0 °C
  
> set temperatur
Fig. 4.15 Display screen   8 (example)
The display shows "Select temperature" as an 
explanation.
 
Click the right-hand dial.
The field is highlighted.
 
Turn the right-hand dial until the desired 
value is displayed (values from 5 °C to 30 °C in 
half degree steps are possible).
 
Click the right-hand dial.
The required set-back temperature is set. The display 
changes from inverse back to normal.
4 Operation
16