Vaillant VRT 360f Operating and Bedienungsanleitung

Seite von 48
22
Operating manual VRT 360f
Display
Required steps
¬ Holiday function
Holiday function
If you want to deactivate the 
function before, just press the F 
button. If the anti-legionnaire's 
disease function is activated, it is 
performed on the last day of the 
holiday.
Table 4.4 Special functions
4.7 Info 
level
Press the info button to access the info 
level. The info symbol appears in the 
display as soon as you open the info 
level. Each time you press the button, 
different information is displayed:
-  The name of the room temperature 
thermostat (VRT 360f )
-  The quick veto room temperature (if 
active)
-  The set room temperature T-H1 (if 
activated - e.g. T-H1 20.0 °C)
-  The set room temperature T-H2 (if 
activated - e.g. T-H2 23.0 °C)
-  The set room temperature T-H3 (if 
activated - e.g. T-H3 18.0 °C)
-  The required room temperature if the 
temperature level function is not 
activated (e.g. TEMP 20.0 °C)
-  The set set-back temperature 
(e.g. ECO 15.0 °C)
-  The set hot water temperature 
(e.g. DHW 60 °C)
4 Operation