Utica Boilers HL Servicehandbuch

Seite von 1
 
World Headquarters • 2201 Dwyer Ave. • P.O. Box 4729 • Utica, New York 13504-4729 
Ph: 315/797-1310 • Fax: 315/797-3762 • E-Mail: 
information@ecrinternational.com
 • Web: www.ecrinternational.com 
 
 
 
 
 
 
 
 
 
   
   
 
 
 
 
 
 
 
          
BULLETIN NO. 060506
 
DATE: June 5, 2006 
 
 
 
 
     
 
PRODUCTS: Utica Boilers - Hotline Series Indirect Water Heater 
FROM: ECR Technical Service Department 
Subject: Coil Change 
Models Effected: 
HL-30, 40, 50, 80 & 119 
 
Description of Change 
Effective immediately the HotLine Series Indirect Hot Water Heaters have changed as follows: (see illustration below) 
•  HL30, HL40 & HL50 have relocated their “boiler/coil in” and “boiler/coil out” tapings. Previously on the top, these 
connections are now on the side of the tank. 
•  All HotLine sizes (HL30 - HL119): Internal coil diameters have increased from ¾” to 1-¼”
Coil connections for all 
sizes will now be 1-inch NPT. 
NOTE: 
The change in the coil does not effect the location or size of the domestic Hot and Cold connections.
 
 
 
                            
 
 
 
 
     
 
 
 
 
 
 
 
 
Reasons for Coil Change 
•  Better heat transfer due to more coil surface area resulting in improved output (recovery rate) of the tank. 
•  Improved flow through coil due to lower head loss. 
 
Product Description and Model Numbers 
(Note: Trade Prices have not changed) 
 
OLD  
DESCRIPTION 
OLD MODEL #
NEW  
DESCRIPTION
NEW MODEL # 
HL30CT ST00201 HL30SK ST00211 
HL50CT ST00202 HL50SK ST00212 
HL80CT ST00203 HL80SK ST00213 
HL119CT ST00204 HL119SK ST00214 
HL40CT ST00205 HL40SK ST00215 
 
For Additional Information 
Please feel free to contact our Technical Service Department at 1-800-325-5479 if you have any questions pertaining to the 
information contained in this bulletin. 