FOR YOUR SAFETY READ BEFORE OPERATING
 WARNING
If you do not follow these instructions 
exactly, a fire or explosion may result 
causing property damage, personal injury 
or loss of life.
• This appliance is equipped with an ignition device 
which automatically lights burner. Do NOT try to 
light this burner by hand.
• Before operating smell all around appliance area 
for gas. Be sure to smell next to floor because 
some gas is heavier than air and will settle to the 
floor.
• Use only your hand to turn the gas shutoff 
valve. Never use tools. If valve will not turn 
by hand, do not try to repair it, call a qualified 
service technician. Force or attempted repair may 
result in fire or explosion.
• Do not use this appliance if any part has 
been under water. Immediately call a qualified 
service technician to inspect appliance and to 
replace any part of control system and any gas 
control which has been under water.
!
  
2.1 Operating Instructions
Stop! Read Safety information above.
• Set thermostat to lowest setting.
• Turn "OFF" all electrical power to appliance.
• This appliance is equipped with an ignition device which 
automatically lights the burner. Do not try to light 
burner by hand!
• Remove front jacket panel.
• Turn gas shutoff valve   to closed position. Handle 
should be perpendicular to gas pipe. See Figures 2-1 
and 2-2.
• Wait 5 minutes for any gas to clear. Smell for gas, 
including near floor. If you smell gas, STOP! Follow 
instructions on this page: “What To Do If You Smell 
Gas.” If you do not smell gas, go to next step.
• Turn gas shutoff valve 
  to the open position. Handle 
should be parallel to gas pipe.
• Replace front jacket panel.
• Turn "ON" electrical power to appliance.
• Set thermostat to desired setting.
• If the appliance will not operate, follow instructions TO 
TURN OFF GAS TO APPLIANCE and call your service 
technician or gas supplier.
CAUTION
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use 
any phone in your building.
• Immediately call your gas supplier from a 
neighbor’s phone. Follow the gas supplier’s 
instructions. 
• If you cannot reach your gas supplier, call the fire 
department.
!
  
2.2 To Turn Off Gas To Appliance
• Set thermostat to lowest setting.
• Turn "OFF" all electric power to appliance if service is 
to be performed.
• Remove front jacket panel.
• Turn gas shutoff valve handle    to closed position. 
Handle should be perpendicular to gas pipe. See Fig-
ures 2-1 and 2-2.
• Replace front jacket panel.
2 - OPERATING INSTRUCTIONS
2-1 Gas Shutoff Valve Outside Boiler Jacket (view from 
top rear of boiler) 
Supplied Manual 
Main Gas
Shutoff Valve  
(shown in open 
position)
PIPE
PIPE
GAS SHUTOFF 
VALVE
GAS SHUTOFF 
VALVE
2-1 Gas Shutoff Valve  - Closed Position