Sterling Welder 882.00274.00 Benutzerhandbuch
Additive Feeders
Chapter 7: Appendix
40 of 50
7-3 Technical
Specifications
Annex B Information
The following design information is provided for your reference:
The following design information is provided for your reference:
1. No modifications are allowed to this equipment that could alter the CE compliance
2. Ambient temperature:
0 degrees Celsius – Maximum (104 degrees Fahrenheit)
3. Humidity range:
50% relative humidity
4. Altitude:
Sea
level
5. Environment:
Clean, dust-free and non-explosive
6. Radiation:
None
7. Vibration:
Minimal,
i.e.
machine
mounting
8. Allowable voltage fluctuation:
+/- 10%
9. Allowable frequency fluctuation:
Continuous
+/- 1%
Intermittent
+/-
2%
10. Nominal supply voltage:
460/3/60 (Verify on serial number tag)
11. Earth ground type: TN (system has one point directly earthed through a protective conductor)
12. Power supply should include a ground connection.
13. Over-current protection is supplied in the additive feeder, but additional protection
should be supplied by the user.
14. The door-mounted disconnect serves as the electrical disconnect device.
15. Additive feeder is not equipped with local lighting.