Con nec tion of an alarm horn to an ex ter nal source of power
»
Be fore con nec tion of an ex ter nal power sup ply switch the equip ment off. 
Un plug the mains plug. 
Re move the fuses F4 (= blend ing unit) or F5 (= alarm).
S 150 jumper as sign ment
Ju1:
1-2: Mi cro pro ces sor in power save mode, open (stan dard)
Ju2/3:
1-2 + 2-4: Ma te rial sen sor with open col lec tor out put
2-3 + 4-5: Ma te rial sen sor with source driver (stan dard)
Ju4/6:
1-2: Ex ter nal RS422 sup ply
2-3: In ter nal RS422 sup ply (stan dard)
Ju5:
1-2: Set value 0-10 kHz (stan dard), 
2-3: Set value 0-10 V, 0-20 mA
Ju7:
1-2: Set value 0-20 mA, 
2-3: Set value 0-10 kHz (stan dard) or 0-10 V
Ju10:
Equip ment sup ply volt age 115 V
Ju11:
Equip ment sup ply volt age 230 V (stan dard)
1
7
6-
1
M
S
SDD 1 SGM
Elec tri cal  ma nu al  10-9
J15
J16
J9*
J10 J11 J12 J13 J14
J17
Ju7
1
Ju2
Ju3
1
1
Ju5
1
Ju4
Ju6
1
1
Ju1
F2
F3
Ju10
115V
Ju11
230V
F7
F1
F5
F4
J8*
L
PE
N
L'
* from serial number 031.03-0108162090 
onwards 5 terminals