To ensure that the MP modem meets Health Canada’s Safety 
Code 6 requirements, a separation distance of at least 20 cm 
(8 inches) must be maintained between the modem’sMain RF 
antenna and the body of the user and any nearby persons at all 
times and in all applications and uses. 
Additionally, the maximum antenna gain in the PCS band, 
including cable loss, must not exceed 4.15 dBi, and in the 
Cellular band, must not exceed 5.1 dBi, to comply with 
Industry Canada and Health Canada regulations limiting both 
maximum RF output power and human exposure to RF 
radiation.
For the MP 595 modem, the maximum gain for the AP antenna 
must not exceed 3 dBi, and the AP antenna must be at least 20 
cm away from the Main RF antenna.
U.S.A.
To comply with FCC regulations limiting both maximum RF 
output power and human exposure to RF radiation, the 
maximum antenna gain, including cable loss, in the PCS band, 
must not exceed 4.15 dBi, and in the Cellular band, must not 
exceed 5.1 dBi. 
The Main RF Main RF antenna must be mounted such that 
there is a separation distance of at least 20 cm (8 inches) 
between the Main RF antenna and the body of the user or any 
nearby persons.
For the MP 595 modem, the maximum gain for the AP antenna 
must not exceed 3 dBi, and the AP antenna must be profes‐
sionally installed with a separation distance of at least 20 cm 
away from the Main RF antenna, per FCC Part 15 require‐
ments.