PFA CONTROLLER report
SM2 reports
PFA CONTROLLER report
This report provides detailed monitored data on a single PFA cache served by PCA and
whose pubset disks can be assigned to various controllers.
Report output
The PFA CONTROLLER report is output only at the explicit request of the SM2 user with
the help of the SELECT-PFA-CACHE statement (see page 179). The PFA CACHE report
indicates the caches for which subreports can be selected. In addition to the PFA CACHE
report, this statement is used to output a PFA CONTROLLER report for the selected
caches. The PFA CONTROLLER report supplies detailed information on the cache
controllers.
The report can only be output if the SM2 administrator has activated the monitoring process
using the statement START-MEASUREMENT-PROGRAM TYPE=*PFA.
Overflow screens may be requested for this report.
The monitored data output is sorted under the categories READ and WRITE.
It is possible to output data on up to 16 caches.
Monitoring information
CACHE ID
Cache ID. This is identical with the PVS ID of the pubset served.
CONTROLLER TYPE 3419
3421
3860
SYMMETRIX
D016ZE04 SM2 PFA CONTROLLER      CYCLE:   60 S               99-04-11  15:08:00
   CACHE-ID: 1MD3         CONTROLLER-TYPE: 3860        PREFETCH LENGTH: NONE
  | CTL  | #DEV | SEC |   SIZE   |  READ  | RD HIT| WRITE  | WR HIT|OVERRUNS|
  |  MN  |      | NR  |          |  (1/S) |  (%)  | (1/S)  |  (%)  | (1/S)  |
  +------+------+-----+----------+--------+-------+--------+-------+--------+
  |   00 |   8  |   0 |     0 MB |  317.8 |  99.7 |  106.9 |  99.3 |    0.5 |
  +------+------+-----+----------+--------+-------+--------+-------+--------+