Siemens TC63 Benutzerhandbuch

Seite von 501
TC63 AT Command Set  
8.4 AT+CREG
s
TC63_ATC_V00.490
Page 184 of 501
5/24/05
Confidential / Draft - Do not copy
 
8.4
AT+CREG Network registration
Th
 command serves to verify the network registration status of the ME. For this purpose two types of
URCs are available. 
The 
 read command returns the URC presentation mode 
 and an integer 
 that shows the
registration status of the ME. The location information elements 
 are returned only when 
and ME is registered to the network. 
Syntax
Unsolicited Result Codes
 URC 1
If 
=1 and there is a change in the ME network registration status: 
+CREG: 
 URC 2
If 
=2 and there is a change in the ME network registration status or a change of the network cell: 
+CREG: 
[, 
]
Parameter Description
[0]
(&F)
Disable +CREG URC
1
Enable URC +CREG:
 to report status of network registration 
2
Enable URC +CREG:
[,
,
tration including location information. Optional parameters 
 an
will not be displayed during calls or if these values have not changed since last
 read command or since last indication by +CREG URC. 
Test Command
AT+CREG=?
Response(s)
+CREG: 
(list of supported
OK
Read Command
AT+CREG?
Response(s)
[, 
]
OK
ERROR
+CME ERROR: <err>
Write Command
AT+CREG=
[
Response(s)
OK
ERROR
+CME ERROR: <err>
Reference(s)
PIN
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
4
Last
GSM 07.07
!
%
%
%
%
%
%
!
!
!
<n>
(num)(&W)(&V)