8.10.1 AT^SMONG Cell Info Table
Example output for 
Columns of the cell info table:
GPRS Monitor
BCCH  G  PBCCH  PAT MCC  MNC  NOM  TA      RAC          # Cell  #
0637  1  -      4   234  05   2    00      0B
Column
Description
BCCH
ARFCN of BCCH carrier
G
GPRS status:
0     GPRS not available in currently used cell
1     GPRS available in currently used cell
2     GPRS attached
Note: During a voice call or CSD connection, GPRS services are not available, and con-
sequently G=0 is displayed. 
PBCCH
If PBCCH is present, indication of ARFCN, else ''-'' or if Frequency Hopping is used ''H''
PAT
Priority Access Threshold (GSM Rec. 04.08 / 10.5.2.37b)
0     Packet access is not allowed in the cell
1     Spare, shall be interpreted as "000" (packet access not allowed)
2     Spare, shall be interpreted as "000" (packet access not allowed)
3     Packet access is allowed for priority level 1
4     Packet access is allowed for priority level 1 to 2
MCC
Mobile Country Code
MNC
Mobile Network Code
NOM
Network Operation Mode (1...3)
TA
Timing Advance Value
RAC
Routing Area Code (as hexadecimal value)