Siemens TC63 Benutzerhandbuch

Seite von 501
TC63 AT Command Set  
13. Short Message Service (SMS) Commands 
s
TC63_ATC_V00.490
Page 319 of 501
5/24/05
Confidential / Draft - Do not copy
 
13.
Short Message Service (SMS) Commands
The AT Commands described in this chapter allow an external application to use the Short Message Service with
the TC63. 
13.1
SMS parameters
Parameter Description
Format is same for 
 in case of SMS, but without GSM 24.11 SC address field and parameter shall be
bounded by double quote characters like a normal string type rarameter 
String type alphanumeric representation of 
 or 
 corresponding to the entry found in phonebook; imple-
mentation of this feature is manufacturer specific 
Command Data
GSM 03.40 TP-Command-Data in text mode responses; ME/TA converts each 8-bit octet into two IRA character
long hexadecimal numbers (e.g. octet with integer value 42 is presented to TE as two characters 2A (IRA 50
and 65)) 
Command Type
GSM 03.40 TP-Command-Type in integer format 
[0]...255
Destination Address
GSM 03.40 TP- Destination-Address Address-Value field in string format; BCD numbers (or GSM default alpha-
bet characters) are converted into characters; type of address given by 
User Data
In case of SMS: GSM 03.40 TP-User-Data in text mode responses; format:
• If 
 indicates that GSM 03.38 default alphabet is used and 
 indicates that GSM 03.40 TP-User-
Data-Header-Indication is not set: ME/TA converts GSM alphabet into current TE character set according to
rules covered in Annex A.
• If 
 indicates that 8-bit or UCS2 data coding scheme is used, or 
 indicates that GSM 03.40 TP-
User-Data-Header-Indication is set: ME/TA converts each 8-bit octet into hexadecimal numbers con-taining
two IRA characters (e.g. octet with integer value 42 is presented to TE as two characters 2A (IRA 50 and 65).
In case of CBS: GSM 03.41 CBM Content of Message in text mode responses; format:
• If 
 indicates that GSM 03.38 default alphabet is used: ME/TA converts GSM alphabet into current TE
character set according to rules covered in Annex A.
• If 
 indicates that 8-bit or UCS2 data coding scheme is used: ME/TA converts each 8-bit octet into hexa-
decimal numbers containing two IRA characters.
<ackpdu>
(num)
<alpha>
(str)(+CSCS)
<cdata>
(num)
<ct>
(num)
<da>
(num)(+CSCS)
<data>
(num)(+CSCS)