Siemens TC63 Benutzerhandbuch

Seite von 501
TC63 AT Command Set  
18.15 AT^SNFS
s
TC63_ATC_V00.490
Page 428 of 501
5/24/05
Confidential / Draft - Do not copy
 
18.15
AT^SNFS Select audio hardware set
Th
 write command serves to set the audio mode required for the connected equipment. 
 can also be used in conjunction with 
. This is useful, for example, if the audio interfaces are
operated alternatively to benefit from different devices. Each audio mode can be assigned a specific interface.
To do so, first select the audio mode with 
, then activate the audio interface with 
 and finally
ente
 to store the settings to your audio profile. To switch back and forth it is sufficient to use 
Syntax
Parameter Description
[1]
Audio mode 1: Standard mode optimized for the reference handset, that can
be connected to the analog interface 1 (see "TC63 Hardware Interface
Description" for information on this handset.) To adjust the volume use the
knob of the reference handset. In audio mode 4, this handset can be used with
user defined parameters.
Note: The default parameters are determined for type approval and are not
adjustable with AT commands. 
 restores 
 1. 
2
Audio mode 2: Customer specific mode for a basic handsfree (speakerphone)
device (Siemens Car Kit Portable).
Analog interface 2 is assumed as default.
3
Audio mode 3: Customer specific mode for a mono-headset.
Analog interface 2 is assumed as default. 
4
Audio mode 4: Customer specific mode for a user handset.
Analog interface 1 is assumed as default. 
5
Audio mode 5: Customer specific mode. 
Analog interface 1 is assumed as default. 
6
Audio mode 6: Customer specific mode.
Analog interface 2 is assumed as default. 
Test Command
AT^SNFS=?
Response(s)
^SNFS: 
(list of supporte
s) 
OK
Read Command
AT^SNFS?
Response(s)
OK
Write Command
Response(s)
OK
ERROR
CME ERROR: <err>
Reference(s)
PIN
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
4
Last
SIEMENS
!
%
%
%
%
%
%
!
%
!
<audMode>
(num)(^SNFW)