Siemens TC63 Benutzerhandbuch

Seite von 501
TC63 AT Command Set  
19.5 AT^SCTM
s
TC63_ATC_V00.490
Page 444 of 501
5/24/05
Confidential / Draft - Do not copy
 
19.5
AT^SCTM Set critical operating temperature presentation mode 
or query temperature
Use this command to monitor the temperature range of the module and the battery. The write command enables
or disables the presentation of URCs to report critical temperature limits.
CAUTION: During the first 15 seconds after start-up, the module operates in an automatic report mode: URCs
can be always displayed regardless of the selected mode 
Syntax
Unsolicited Result Codes
 URC 1
URCs will be automatically sent to the TA when the temperature reaches or exceeds the critical level, or when
it is back to normal. 
^SCTM_A: 
for battery temperature
 URC 2
^SCTM_B: 
for module (board) temperature
Test Command
AT^SCTM=?
Response(s)
^SCTM:
(list of supported 
s)
OK
Read Command
AT^SCTM?
Response(s)
OK
ERROR
+CME ERROR
Write Command
Response(s)
OK
ERROR
+CME ERROR
Reference(s)
PIN
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge
4
Last