Sanyo MTR-5000 Merkblatt

Seite von 2
Dimensions MTR-L03
[Unit : mm  (inch)]
Specifications
Main functions
Data Acquisition System
Distributed by:
©2009 SANYO Printed in Japan 2009.7 MA
SHR147
SANYO Electric Co., Ltd.
Biomedical Division
http://biomedical.sanyo.com/
Set Value Information
Set values of SANYO biomedical devices can 
be changed through the network.
*The above function is only applicable to remote-
controllable devices.
Map Display
Conditions of biomedical devices can be 
displayed on the map intelligibly. (A device 
showing a warning is displayed in red.)
Graph Display
Condition change of a selected channel can be 
displayed on a graph.
Channel List
The condition of each channel (measurement 
item) is displayed together with the upper and 
lower limit setting data.
• SANYO cannot guarantee operations of all PCs satisfying the 
above recommendable specifications.
• If other software is installed in a PC in which this software 
was installed, information may be deleted due to malfunction.
Caution: SANYO guarantees the product under certain 
warranty conditions. SANYO in no way shall be responsible for 
any loss of content or damage to content.
• Appearance and specifications are subject to change without 
notice.
65 (2.6”)
74 (2.9”)
58 (2.3”)
28 (1.1”)
63 (2.5”)
• Device-related information such as 
temperature, CO
2
 and O
2
 concentration, 
and operating condition can be 
integratedly monitored with one LAN-
connected personal computer.
Items that can be monitored depend on the 
connected devices.
• Operating records are stored in 
sequence in the PC. It is unnecessary to 
fill in paper records or to enter in a 
record book. It is easy to convert the 
data into a graph.
Please note that there is a case in which data must 
be recorded on a paper.
• Devices can be set up remotely from a 
distant point, which saves entering a 
clean room.
When the operating setting can be changed through 
the network, it is impossible to change the 
operation setting on the panel of each device.
• Setting the upper/lower limits will cause 
you to be informed of an abnormality by 
e-mail if the data is out of the range, and 
you will also be informed when the 
system recovers from the abnormality. 
In addition, the system can be set so 
that the device conditions will be 
informed at a designated time whether 
or not there is an abnormality.
A mail account which can be connected to an 
SMTP-compatible mail server is required.
• Two-step/day operation to set up two 
different temperatures is 
programmable.
For example, energy saving can be expected by 
changing to different setting temperatures for day 
and night operations.
• System access is protected by 
ID/Password.
Features
SANYO Electric Co., Ltd., Biomedical Division, Gunma is certified for: 
Quality management system: ISO9001 / Medical devices quality management system: ISO13485 / Environmental management system: ISO14001
Note: 
All screen images shown in the catalog are composite images.
In the unlikely event of a mechanical failure, the contents of 
the incubator and any recorded data cannot be guaranteed.
Model
Product name
Exterior 
dimensions
(W x D x H)
Power supply
Output terminal
Compatible 
protocol
Note
Model
Product name
No. of devices to 
be monitored
Devices to be 
monitored
Monitoring PC
Recommendable 
specifications
MTR-L03
Ethernet (LAN) Interface
74 x 63 x 58mm
(2.9” x 2.5” x 2.3”)
DC5V (to be supplied from the 
attachment device)
RJ-45 twist pair cable 8-pin 
connector
TCP/IP *Only static IP 
(Impossible to use DHCP.)
MTR-L03 is not equipped with 
sensors for temperature, etc. As 
information such as in-box 
temperature, etc., results 
measured at the sensors of the 
incubators and freezers are 
transmitted to the network.
MTR-5000
SANYO Data acquisition software
32 devices at most (up to 100 ch)
SANYO biomedical devices 
connected to MTR-L03 or MTR-
480 (RS232C or RS-485)
CPU: Core2DUO or higher
Memory: 1GB or more
HDD: 80 GB or more
OS: Microsoft Windows XP SP3
(compatible with Windows Vista)