On the front cover of the receiver you will
see that there is the On/Off switch and two
Light Emitting diodes (LEDs). The switch
allows you to turn off the receiver if
necessary to prevent it calling for heat. The
top LED (red) will illuminate when the
switch is in the ‘On’ position and the unit is
receiving power. The top LED (green)
illuminates when the receiver is
receiving a heat call transmission from the
thermostat. The wiring terminals and RF Address Code setting DIP switches
are located on the rear of the receiver, as shown above:
RECEIVER WIRING TERMINALS
Terminal Identifier Description
1
NO
Normally Open (N/O) Volt free contacts
2
COM
Common terminal (COM) Volt free contacts
3
L
Live supply (230V AC)
4
N
Neutral
TYPICAL WIRING INSTALLATIONS
The RT receiver is wired the same
way no matter if you are wirings
230V or 24V, the receiver will
always need a 230V Live and
Neutral feed connected into L &
N terminals. The COM and NO is
to be connected to the boilers
external loop (see diagram
below), if connected in this way
the receiver relay can only switch
voltage supplied by the boiler.
RECEIVER
BOILER
MAINS
FEED
N
L
N.O.  COM  L  N
Thermostat loop 
(Remove link)
Live Feed
N
L
SL
L
N
E
RXRT505 INSTRUCTION MANUAL
6