Ricoh FV-G200B1 Benutzerhandbuch

Seite von 38
 
 
 
 
 
11/38 
FV-G200B1 
User’s Guide Rev. 1.02 
 
3.  Camera Opeartional Modes 
 
3.1 
Normal Mode 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
3.2 
Pulse Width Trigger Mode 
 
In  this  trigger  mode  with  positive  polarity,  the  camera  exposure  starts  at  the  rising  edge  of  the  trigger  pulse  and 
stops at the falling edge of the trigger pulse. Therefore, if positive polarity exposure is selected, the exposure periods 
are the high states of the trigger pulse. 
 
3.2.1 
Timing 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Note 1: The video output is going to be V reset by the next internal HD signal immediately after the exposure is finished. 
The exposure time is set by the pulse width of the trigger signal. 
Note 2: The FVAL signal does not output when the exposure by the trigger signal does not exist. 
Ex p o s u r e
t i me
I n t e r n a l   VD
CCD
e x p o s u r e
Vi d e o   o u t
Exposure
time
Max. 1H
Internal VD
CCD exposure
Trigger signal
(Positive)
Video out
*Note. 1
*Note. 2
FVAL