3.3.2 
Exposure Timing with the Positive Polarity Trigger Signal 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Note 1: The trigger signal will be removed by the filtering if the pulse width of the input trigger signal is less than 30 CLK. 
Please input a trigger signal with more than 31 CLK pulse width. 
Note 2: The exposure will start 105 CLK after the rising edge of the trigger signal. 
 
3.3.3 
Exposure Timing with the Negative Polarity Trigger Signal 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Note 1: The trigger signal will be removed by the filtering if the pulse width of the input trigger signal is less than 30 CLK. 
Please input a trigger signal with more than 31 CLK pulse width. 
Note 2: The exposure will start 105 CLK after the rising edge of the trigger signal. 
Input Trigger signal
Exposure time
T1'
SUB
SG
Exposure tim: T1' = Preset exposure time
Filtering *Note.1
30 CLK
Less than
5useconds
Trigger signal
(With Photocoupler delay
75 CLK
Input Trigger signal
Exposure time
T1'
SUB
SG
Exposure tim: T1' = Preset exposure time
Filtering *Note.1
30 CLK
Less than
60 useconds
Trigger signal
(With Photocoupler delay
75 CLK