Ricoh FV-G200B1 Benutzerhandbuch

Seite von 38
 
 
 
 
 
19/38 
FV-G200B1 
User’s Guide Rev. 1.02 
 
The description of the format is as follows. 
 
Name 
Descriptions 
SOF 
Start of Frame. Always set or receive the value as “02H”   
Device Code 
This indicates the destination of communication. 
 
Set “000000” when accessing the camera’s function settings 
Set “100000” when accessing the camera’s extended function settings. 
Please  refer  to  the  “Camera  Command  List”  and  “Description  of  the  Camera  Control 
Commands”. 
Read / Write 
This specifies “Read” or “Write” to command numbers. 
 
Set (or receive) “0” to send the read command. 
Set (or receive) “1” to send the write command. 
Page 
Selection 
This specifies page selection (access selection to registers or EEPROM) of command. 
 
Set “0” to access the command register of the camera. 
        Read command: To obtain the current data from the command register. 
        Write command: To set a data into the command register.   
The previously stored data is replaced by this data. However, the data in the EEPROM is not 
replaced. 
 
Set ”1” to access the EEPROM of the camera. 
        Read command: To read stored data from the EEPROM. 
        Write command: To store data into the EEPROM as default value. 
The camera returns the receiving code “01H” to the PC after storing data in the EEPROM. 
Command 
Code 
This  indicates  the  contents  of  the  data  sent  or  received.  Refer  to  the  following  page  for  the 
details. 
Data Length 
This indicates the data length (unit: byte). 
 
Receiving Frame: 
The data length is dependent on each read command sent.   
The data length is defined as “00H” when sending the write command.   
The data length of error response is defined as “00H”.   
 
Sending frame: 
The data length is 1 byte dummy data when sending the read command, and that data is 
not referenced.   
The data length is dependent on each “write command” sent. 
Data 
This indicates write data or read data according to command type. 
EOF 
End of Frame. Always set or receive the value as “03H” 
Receiving 
Code 
This indicates results of the command sent 
 
01H: OK (ACK),    10H: NG (NAC),      12H: Command number error (Not matching), 
13H: Communication frame error (only for Gamma data upload), 
14H: Time out error (Two seconds), 
15H: Check sum error (only for Gamma data upload), 
16H: Data length error (Not matching),      17H: EEPROM write error