Ricoh FV-G200B1 Benutzerhandbuch
![Ricoh](https://files.manualsbrain.com/attachments/5d75c15ccccf2674dc37d8acfe0fae2e288880f8/common/fit/150/50/7e2e9af8081fa1a72a9fce0a1dbc35e689c173f116f15720716c2ad6d183/brand_logo.png)
14/38
FV-G200B1
User’s Guide Rev. 1.02
User’s Guide Rev. 1.02
3.3.2
Exposure Timing with the Positive Polarity Trigger Signal
Note 1: The trigger signal will be removed by the filtering if the pulse width of the input trigger signal is less than 30 CLK.
Please input a trigger signal with more than 31 CLK pulse width.
Note 2: The exposure will start 105 CLK after the rising edge of the trigger signal.
3.3.3
Exposure Timing with the Negative Polarity Trigger Signal
Note 1: The trigger signal will be removed by the filtering if the pulse width of the input trigger signal is less than 30 CLK.
Please input a trigger signal with more than 31 CLK pulse width.
Note 2: The exposure will start 105 CLK after the rising edge of the trigger signal.
Input Trigger signal
Exposure time
T1'
SUB
SG
Exposure tim: T1' = Preset exposure time
Filtering *Note.1
30 CLK
Less than
5useconds
Trigger signal
(With Photocoupler delay
75 CLK
Input Trigger signal
Exposure time
T1'
SUB
SG
Exposure tim: T1' = Preset exposure time
Filtering *Note.1
30 CLK
Less than
60 useconds
Trigger signal
(With Photocoupler delay
75 CLK