Ricoh A12 Benutzerhandbuch

Seite von 64

Cleaning the sensor unit
Follow the steps outlined below to clean the sensor.
1  Turn on the power.
2  Slide the POWER switch to OFF while pushing the
N button.
•  Turn off power with the shutter left open.
3  Clean the unit using a blower from a camera supply store.
4  Once done cleaning, turn the power on and then off again.
 Caution ----------------------------------------------------------------------------------
•  Do not touch the sensor or shutter.
•  The color may fade if the sensor is subjected to intense light for long 
periods of time. Do not let the camera sit with the shutter open.
•  When the [Shutter Initial Sel.] in the setup menu is set to [OPEN], the 
shutter remains open when the power is turned off.
•  Do not use a spray blower with this device.
•  Do not insert the nozzle of the blower inside past the mount.
•  Damages during cleaning will not be covered by warranty.
  Be careful not to damage the device while cleaning it.