OUTPUT 
. . . . . . . . . 
COMMANDS
The table below lists all DGy 201x output commands, their arguments 
and detailed descriptions. 
Table 6-5  
Output Commands  
Command
Arguments
Description
GAMma
<0.5...2.0>
Sets the playback gamma. 
Default: 1.0
OUTPUT 
(none)
A query command which returns information on the 
current output timing.
OutPutTiMingLOAD
<1..160>
Sets the output raster to the timing selected from 
the Timing List. In order to load the output timing 
parameters the DGy 201x must be in the FreeRun 
mode.
)
Refer to 
OutPutTiMingNAME
<name>
Assigns a name to the current output timing. The 
argument can be up to 23 alphanumeric characters 
with no spaces (underscore is acceptable).
OutPutTiMingSAVE
<100..160>
Saves the timing data of the current output raster 
into the Timing List. The argument specifies which 
Timing List position is used. 
If 
OutPutTiMingSAVE
 is issued for an already 
occupied position, the DGy requests overwrite 
confirmation.
Refer to the 
additional details.
OutPutTiMing
<hfp> <hs> <hbp> 
<hact> <vfp> <vs> 
<vbp> <vact> <hfreq> 
<sync> <hpol> <vpol> 
<il>
Sets the timing for the current output. 
OutPutTiMing
(Alternate)
<HFP | HS | HBP | 
HACT | VFP | VS | VBP 
|VACT| HFREQ| SYNC | 
HPOL | VPOL | 
IL>[<value>]
Changes (or reports) one parameter of the current 
output timing.