PROLINK Huricane 9200/S Benutzerhandbuch

Seite von 205
Hurricane 9200/S ADSL Ethernet Router User’s Guide 
 
154
 
Field 
Description 
Cmp. Type 
Comparison Type - The method for comparing the 
selected bits, after the mask is applied, to a reference 
value (or range of values) that you specify (see the 
next setting). Compared to the reference value, the 
selected bits can be: 
o
  eq: equal to 
o
  neq: not equal to 
o
  lt: less than 
o
  lteq: less than or equal to 
o
  gt: greater than 
o
  gteq: greater than or equal to 
o
  range: any source IP address that is within the 
specified range, including its endpoints. 
o
  any: all packets of any type will match this 
subrule. This selection makes irrelevant any 
other criteria in the subrule. 
 WARNING:  The comparison type any should only 
be used when all packets of any type are to be 
accepted or denied. This selection, combined with a 
rule type that denies matching packets, may disable 
your access to the Web interface. 
Lower 
Value/Higher 
Value 
The reference values, in hexadecimal, to which the 
selected bits will be compared. If range is selected as 
the comparison type, enter values in both fields; 
otherwise enter a value only in the Lower Value field. 
 
7.  When you are finished entering criteria and are ready to 
make this subrule effective, you can click the Enable radio 
button at the top of the Bridge Filter Subrule - Add page and 
then click 
. (You could also leave it disabled and 
edit the subrule to enable it later.) 
A page displays to confirm your changes. 
8.  Click 
 to return to the Bridge Filter Configuration 
Page. The subrule should now display in the table beneath 
the general rule it was added to. 
Next, if you have not already done so, you can enable the rule, any 
of its subrules, and the bridge filtering service in order to make the 
rule effective. 
On the Bridge Filter Configuration page, a red ball displays in the 
Oper. Status column of the table for rules and subrules that are 
disabled, and a green ball displays for rules that are enabled. 
(When creating rules and their subrules, you may have chosen to 
leave them disabled - the default.) 
To make a rule active, enable the following three settings: 
 
The Bridge Filter service
: At the top of the Bridge Filter 
Configuration page, click the Enable radio button.  
 
The rule
: On the Bridge Filter Configuration page, click 
 
in the Actions column in the row for the rule. On the Bridge