Parker Products COMPAX-M /-S (L) Benutzerhandbuch

Seite von 242
Operating Instructions
COMPAX-M / -S
Digital inputs and outputs
146
Logical inputs * 
I1...I8 
Field bus I17...I24 
Logical inputs * 
I9...I16 
Field bus I25...I32 
≥≥≥≥
1
 
="0" 
P222 
="1" 
="0" 
P221 
="1" 
COMPAX –  
control functions 
Depends on COMPAX 
device variants (for 
P222=”0” corresponds to 
arrangement of inputsIE9 
to I16) 
COMPAX - control 
functions  
(for P221=”0” 
corresponds to 
arrangement of inputs I1 
to I8) 
 
SHIFT, Hand+, Hand-, 
Quit, Start, Stop, 
approach Mn, approach 
RN, Tech RN 
logical I1...I8 
logical I9...I16 
logical 
I9...I16 
COMPAX–command 
I41...I48 
(OTA41...OTA48) 
Structural diagram: Access to
COMPAX control functions via
inputs
The logic inputs I1 ... I16 are,
excluding COMPAX 1000SL, also
the physical inputs I1 ...I16 on
connectors X8 and X10.
With COMPAX 1000SL, the 8
physical inputs on connector X19
are allocated (via parameters P156
... P158) to 8 logic inputs from the
range I1 ... I16 (see Page 140)
Remarks regarding the structural diagram
 
The control functions corresponding to I1.. I8 cannot be activated via OT
O33...OT O40.
 
The control functions corresponding to I9...I16 can be activated simultaneously
via the physical inputs and via OT O41...OT O48.
 
The enable input I12 (in COMPAX 1000SL, COMPAX XX70 and COMPAX XX30)
must also be activated when allocated to the fieldbus (via P222).
Interrogation of inputs in the COMPAX program (IF I ..)
All inputs can be interrogated independently of parameters P221 and P222 in the
COMPAX program with IF I... .
The virtual inputs I33...I48 in the COMPAX program can also be set via the
commands OT O33...OT O48.
COMPAX–command 
I33...I40 
(OTA33...OTA40) 
COMPAX–command 
I41...I48 
(OTA41...OTA48) 
Logical inputs * 
I1...I8 
Field bus I17...I24 
Logical inputs * 
I9...I16 
Field bus I25...I32 
COMPAX – program  
Interrogation of inputs with 
IF I1= 
To 
IF I48= 
 
Regardless of parameters 
P221 and P222 
With P233=48 (or P234=48), virtual inputs I48 – I25 are written to the optimization
display status S13 (S14). Meaning: I25 = bit 0 ... I48 = bit 23.