CONVERSIONS
10) REPLACING THE INJECTORS
The burners can be adapted to different types of
gas by mounting injectors suited to the type of gas
in question. To do this, first remove the burner
tops using a wrench "B". Now unscrew injector "A"
(see fig. 13) and fit a injector corresponding to the
utilized type of gas in its place.
It is advisable to strongly tighten the injector in
place.
After the injectors have been replaced, the burners
must be regulated as explained in paragraphs 9.
The technician must reset any seals on the
regulating or pre-regulating devices.
The envelope with the injectors and the labels can
be included in the kit, or at disposal to the
authorized customer Service Centre.
For the sake of convenience, the nominal rate table
also lists the heat inputs of the burners, the diameter of
the injectors and the working pressures of the various
types of gas.
BURNER ARRANGEMENT ON THE HOT PLATE
TABLE
FIG. 13
1
ULTRA RAPID
G 30 - BUTANE
28 - 30
225
90
1400
3100
62
G 31 - PROPANE
37
222
90
1400
3100
62
G 20 - NATURAL
20
295
121 Y
1400
3100
Adj.
2
RAPID
G 30 - BUTANE
28 - 30
204
83
800
2800
45
G 31 - PROPANE
37
200
83
800
2800
45
G 20 - NATURAL
20
267
117 S
800
2800
Adj.
3
SEMIRAPID
G 30 - BUTANE
28 - 30
127
65
500
1750
35
G 31 - PROPANE
37
125
65
500
1750
35
G 20 - NATURAL
20
167
97 Z
500
1750
Adj.
BURNERS
N° 
DESCRIPTION
GAS
NORMAL
PRESSURE
NORMAL
RATE
INJECTOR
DIAMETER
NORMAL
HEAT INPUT 
(W)
mbar
g/h
l/h
1/100 mm
Min. 
Max.
1/100 mm
4
AUXILIARY
G 30 - BUTANE
28 - 30
73
50
400
1000
30
G 31 - PROPANE
37
71
50
400
1000
30
G 20 - NATURAL
20
95
72 X
400
1000
Adj.
BY PASS