Omnia Industries Turntable 6FM Benutzerhandbuch

Seite von 131
 
Omnia 6 Use and Installation Guide – Version 1.00a 
35
35
 
Lock Unit 
Highlight and click to immediately lock the unit. A dialog box is presented for password entry to unlock the 
unit.  
Note: You can only unlock the Omnia-6fm at the same or higher access level than it was at when it was 
locked. In other words, if the unit was locked while at Level 3, then only the Level 3 password will unlock 
the unit. If the unit was at Level 2 when it was locked, then either the Level 2 or the Level 3 passwords will 
unlock it. When the unit is locked at Level 1, then any password will unlock the unit.  
Caution: Do not assign the same password to multiple security levels! You will lock yourself out of the 
unit! 
 
Resetting the Omnia 6 Passwords to their Factory Defaults 
Note: If you do manage to lock yourself out or you have simply forgetten your password, Omnia Technical 
Support can assist you in unlocking your Omnia-6fm. You will need to contact the Telos / Omnia Customer 
Focus Team to obtain a special code which will be entered into the Login Password dialog box. You will 
need to have your Omnia6-fm's 12-digit MAC address (found on the rear panel barcode sticker starting 
with 0050C) and the currently displayed Date (visible just below the Login Password dialog box.) Once 
presented with this information, Omnia Customer Support will give you a special code to type into the 
password dialog box, which will unlock your unit and restore all of the factory default passwords. Note that 
this special password is unique to your unit and is effective for the day on which you call Omnia Customer 
Support to obtain it. 
 
Load Defaults 
Reloads all of the factory default parameters into the system. This is the same as a warm boot command on 
a computer. All Input & Output levels and other System parameters are reset back to their factory default 
settings. 
 
Load From Card 
Allows the system settings (essentially all of the internal parameters except those in the Process Menu), to 
be loaded into the system from the PC Card. When this option has been selected, carefully follow the 
instructions presented on the LCD screen to perform this function. 
 
Save To Card 
This option creates an external file-based backup of your system settings. All parameters except those in 
the Process Menu are included in the System settings. Occasionally doing this is a good safety practice that 
creates a backup of your data; data that is also stored in the nonvolatile RAM within the Omnia-6fm. When 
selected, a naming dialog box appears, allowing you to name files according to the Omnia6-fm from which 
they originated.