Omron D4BL Benutzerhandbuch

Seite von 16
 
Guard Lock Safety-door Switch
 D4BL
A-73
D4
BL
Sa
fe
ty
 Do
or
Sw
it
c
h
e
s
G9SA-301 (24 VAC/VDC) + D4BL-
@G-@ (Solenoid Lock Type) Circuit Diagram (Auto-reset)
Timing Chart
Limit switch S1
S1: 
Safety Limit Switch 
with direct opening mechanism 
(D4B-N, D4N, D4F)
S2: 
Guard Lock Safety-door Switch
KM1 and KM2:  Magnetic Contactor
M: 3-phase 
motor
Guard Lock Safety-door Switch S2
Operation signal
Lock signal
K1 and K2
(NC)
K1 and K2
(NO)
KM1 and KM2
(NC)
KM1 and KM2
(NO)
Guard opens
TH
SA
A1 A2 T11
T12
K1
K1
PE T21
T23
T22
K2
K2
6
a
b
1
2
3
4
5
6
JP
13
T32
T31
23 33 41
2
5
3
1
K1
K2
4
a
b
Control
Circuit
14 24 34 42
A
B
Feedback loop
KM1
KM2
KM1
KM2
M
Operation
instruction
Motor controller
Lock signal
Operation signal
KM1 KM2
31
32
12
11
S2
S1
OPEN
12
11
Note: 1. This example circuit is for Category 4.
2. The lock can be released at any time. Therefore, do not use a model 
with a  solenoid lock in applications where the operator may be 
exposed to danger when the guard opens. Use a model with a 
mechanical lock.