OK International DX-350 / 355 Datenbogen

Seite von 20
 
•  This equipment is for indoor use only 
 
SYMBOL DEFINITIONS 
 
Symbol Definition 
 
Power On/Off 
      
 
Cycle Mode 
 
Timer 
 
     
 
Vacuum  
 
 
Pressure 
 
 
SPECIFICATIONS
 
 
Size 
152mm X 165mm X 178mm 
(6” X 6.5” X 7”) 
Weight 
1.2 kg (2.6 lbs) 
Input Voltage 
24VDC 
Rated Power 
10W 
Air Input 
100 psi (6.9 bar) Max. 
Pollution Degree 
II 
Installation Category 
Indoor Use 
Altitude up to 2,000m (6,562ft) 
Operating Temperature 
0˚C to 50˚C (32˚F to 122˚F) 
Storage Temperature 
-10˚C to 60˚C (14˚F to 140˚F) 
Max. Relative Humidity 
80% for temperature up to 31˚C (87.8˚F) Decreasing 
linearly to 50% relative humility at 40˚C (104˚F) 
Air Output 
DX-350 = 0-100 psi (0-6.9 bar)  
DX-355 = 0-15 psi (0-1.03 bar)  
Vacuum 
406mm (16”) of Hg 
Timer 0.008-60.000 
seconds 
Cycle Mode 
Timed, Interrupt, Teach, Purge  
Timing Repeat Tolerance 
+/- 0.001% 
Cycle Rate 
1,200 cycles/min. 
LCD 
20 X 4 display segments 
 
 
4
FEATURES 
Figure 1.0  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Items Description 
Power Button 
 
Mode Button
 
Reset Button 
Display 
Air Pressure Regulator 
Pulsed Air Outlet   
Vacuum Control
 
Setup Control Knob 
Foot Switch Receptacle 
10 
Receiver Head air hose holder 
11 
Power Receptacle 
12 
 I/O Connection 
13 
Exhaust Port 
14 
Accessory Air Outlet 
15 
Air Inlet  
16 
Cord Lock 
3
7
8
6
5
2
1
4
9
15
16
14
13
10
12
11