CONNECTING THE UNIT 
CAUTION: A 5-micron filter (TSD800-6), not included, must be installed with the unit 
to ensure proper air filtration. 
 
 
 
 
SETUP INSTRUCTIONS 
Refer to Figure 1.0  
6.1 
Manual Dispense Cycle Setting: 
1. 
Turn on the unit by pressing the Power button (1).   
2. 
Press the Mode button (2) until “MANUAL MODE” appears on the 
Display. 
3. 
Turn up the air pressure by rotating the Air pressure regulator knob (6) 
until the desired pressure is indicated on the Air pressure gauge (5).   
4. 
After filling the barrel or using pre-packaged Adhesives, attach syringe 
to receiver head assembly.  Make certain that the syringe locks into 
place. 
5. 
Connect the plug end of the receiver head assembly to one of the air 
dispense outlet (7). 
6. 
If vacuum “suck back” is needed, rotate the Vacuum regulator (8) 
counter clockwise until the desired vacuum pressure is obtained 
7. 
Press and hold the Footswitch to activate dispensed cycle. (The Manual 
Mode is now activated) 
 
6.2   Automatic Dispense Cycle Setting 
1. 
Push the Mode button (2) to select “TIMED MODE”.   
2. 
Press and hold the Set button (3) for two seconds to enter set up 
screen.  The last digit of the dispense time will be highlighted. 
3. 
Press the Set button (3) to move the cursor to the next position.   
4. 
Press the (+) and (-) button to set the time 
5. 
Press and hold the Set button (3) for two seconds to save the data. 
Items Description 
To Air Source 
Air Filter (Not Included) 
3 Power 
Adapter 
4 Foot 
Switch 
Figure 2.0 
2
1
4
3
 
6
6. 
Depress Foot switch to activate timed dispensed cycle. 
 
6.4  Cycle Counter 
The cycle counter records the numbers of automatic dispense cycle being 
activated.  Up to 65,535 cycles can be recorded.  This number is shown at 
the lower right hand corner of the LCD.  To reset the counter, press and 
hold the Set button (3) for two seconds to enter the set mode.  Then press 
and hold the Set button (3) for four seconds to reset the counter. 
 
 
OPERATION DIAGRAM 
 
 
P1
2.250
00004
OFF
P1
2.250
00004
Normal Operation
Power ON/OFF
MODE
Prog
Time Counter
Setup
P1
2.250
00004
SETUP MODE
P1
00004
SETUP MODE
P1
00004
Save and Exit...
SETUP MODE
P1
00004
SETUP MODE
P1
00004
SETUP MODE
P1
00004
SETUP MODE
P1
00004
SETUP MODE
P1
00004
SETUP MODE
P1
00004
P1
00004
P1
2.251
00000
2.250
2
2.250
2
2.250
2
2.250
2
2.251
2
2.250
2
2.251
Save and Exit...
2
2.251
TIME SETTING
COUNTER RESET
:Press then release
:Press and hold for approximately 2 seconds then release
POWER
MODE
SET
Time setting 
:Press and hold for approximately 4 seconds then release
TIMED MODE
TIMED MODE
TIMED MODE
in TIMED MODE
TIMED MODE
MANUAL MODE
Change Mode
*************************
TIMED MODE
2.251