To resolve memory errors when a volume mounts, perform the following actions or ensure that the 
following conditions exist:
Š
Check the status of the available cache buffers. If the cache buffers are fewer than 20%, add 
more RAM to your server. 
Š
Free up memory by unloading resources. 
Š
On volumes using the Traditional file system, streamline the directory structure. Each 
subdirectory takes at least one directory block (by default, a 4 KB block of memory). 
Therefore, subdirectories with only one file require as much memory as directories with 32 
files. Check the 4 KB size. 
For example, you can free up memory by combining few files in many directories into fewer 
directories so that most directories have about 32 files, then purging the deleted subdirectories 
and files.
Š
Calculate how much memory you need and add memory to the server. 
Š
Remove any recently added name space support.
WARNING: This is a destructive step that destroys all the extended file information. Before 
taking this step, try to free up enough memory so that the volume mounts and you can back up 
the data.
Have all users log out, then unload all NLM programs except the volume’s disk drivers. 
Dismount any mounted volumes.
To remove the name space on a Traditional volume, load the Vrepair utility, select Set Vrepair 
Options
, then select the Remove Name Space Support from the Volume and Write All Directory 
and FAT Entries Out to Disk
 options. Exit to the main menu, then run VRepair > Repair a 
Volume
 on the volume that would not mount.
8.8  Resolving Volume Mounting Problems 
Caused by Corrupted Directory Entry Tables or 
File Allocation Tables
To diagnose problems when mismatches exist in the duplicate copies of the FAT and directory entry 
table (DET) on Traditional volumes, identify whether the following conditions exist:
Š
A power failure has occurred and the server has not been shut down with the down command. 
Š
A server disk has failed. 
Š
A disk channel error has occurred. A volume does not dismount when you enter the 
dismount command. 
Š
Directory information in cache is not completely written to disk. 
To resolve problems when mismatches exist in the duplicate copies of the FAT and DET, do the 
following:
Š
Use the Vrepair utility to repair the disk.
Š
Add a UPS system so that the server is shut down automatically when a power failure occurs. 
Š
Replace faulty disks or controllers.