Nortel Networks Circuit Card 311 Benutzerhandbuch

Seite von 1134
Installation and configuration
213
shows the pin assignments when using the NT5D13AA Lineside T1
I/O cable.
Table 100
Lineside T1 card - NT5D13AA Connector pinouts
I/O Panel
Connector
Pin
Lead Designations
NT5D13
AA
Lineside
T1 I/O
Connec
tor
Pin
Lineside T1 cable
connector to external
equipment
1
T1 Tip Receive Data
11
26
T1 Ring Receive Data
3
2
T1 Tip Transmit Data
1
DB15 male to T1 (P2)
Lineside T1 card is CPE
transmit to network and
receive from network
27
T1 Ring Transmit Data
9
3
Alarm out common
1
DB9 male to external alarm
(P3)
28
Alarm out (normally open)
2
4
Alarm out (normally closed)
3
7
Towards MMI terminal
Receive Data
2
31
Towards MMI terminal
Transmit Data
3
DB9 male towards MMI (P5)
Wired as DCE
Data is transmitted on pin 2
(RXD) and received on pin
3 (TXD)
33
Ground
5
8
Control 1
7
32
Control 2
9
33
Ground
5
8
Control 1
7
32
Control 2
9
DB9 female away from MMI
(P4)
Wired as DTE
Data is transmitted on pin 2
(TXD)and received on pin 3
(RXD)
30
Away from MMI terminal
Transmit Data
3
6
Away from MMI terminal
Receive Data
2
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
01.04
Standard
Release 5.0
23 May 2008