Nortel Networks Circuit Card Benutzerhandbuch

Seite von 908
Page 458 of 906
 NT7D16 Data Access card
unless the DTR lead is driven ON by the terminal. Any terminal that drives 
the DTR lead ON can be used with this mode (such as VT100 or VT102).
The DAC drives CTS, DSR, and DCD ON, except when a call is dropped or 
when control—Z is entered during the idle state. In this case, the DAC drives 
those leads OFF for 0.2 seconds and then ON. When the DTR lead is driven 
OFF by the terminal, the DAC does not execute autobaud, nor will it respond 
to any command.
Note: If the PBDO parameter in LD 11 is ON, then Make Set Busy will 
be activated when DTR is driven OFF for more than five seconds.
Programing DAC for mode 12 in service change LD 11
The DAC must be configured as R232 or R422 since Autodial, Speed Call, 
and Display commands are likely to be used.
Figure 94
DAC to Terminal connectivity
pin 2
pin 3
pin 5
pin 6
pin 7
pin 8
pin 20
pin 22
TX
RX
CTS
DSR
GND
DCD
DTR
RI
Terminal (DTE)
DAC (DCE)
RS- 232 leads
>>>
<<<
<<<
<<<
<<<
<<<
>>>
not required
for mode 14