Nortel Networks Circuit Card Benutzerhandbuch

Seite von 908
Page 662 of 906
 NT8D15 E&M Trunk card
trunks. The class of service determines the operation of the switchable pads 
contained in each unit. They are assigned as follows:
TRC for a 2-wire non-VNL trunk facility with a loss of greater than 
2 dB, or for which impedance compensation is provided, or for a 4-wire 
non-VNL facility.
NTC for a 2-wire, non-VNL trunk facility with a loss of less than 2 dB, 
or when impedance compensation is not provided.
See Table 209 for the pad switching control for the various through 
connections and the actual port-to-port loss introduced for connections 
between the E&M trunk card and any other IPE port designated as Port B. 
 shows the pad switching orientation.
 
Table 209
Pad switching algorithm
Port B
Port B pads
E&M Trunk Pads
Port-to-port loss (dB)
Transmit 
D to A
Receive
A to D
Transmit
D to A
Receive
A to D
Port B to 
E&M
E&M to 
Port B
IPE line
N/A
N/A
Out
In
2.5
3.5
Universal trunk 
(TRC)
Out
Out
In
In
0
0
IPE TIE (VNL)
In
Out
In
Out
0
0
Note: Transmit and receive designations are from and to the system. Transmit is from the 
system to the external facility (digital-to-analog direction in the E&M trunk card). Receive is to 
the system from the external facility (analog-to-digital direction in the E&M trunk card).