Cirkuit Planet IPX-300 Benutzerhandbuch

Seite von 84
   Port Num 
Analog Port Number (System Define) 
Caller id 
The caller ID will be sent between the callee and caller and will be 
displayed on SIP device LCD panel for identification. 
DID 
Any calls originating from the registered ITSP to IP PBX will go into the 
auto-attendant or direct to the selected user or hunting group. 
  Table 3-11. Trunk Management - FXO Trunk setup description 
 
 
Gateway Trunk 
Gateway Trunk Setting allows IP PBX makes VoIP calls to external Gateway by peer-to-peer mode. If 
the FXO ports of external Gateway have connected with PSTN lines, the user can make outgoing 
PSTN calls via external Gateway by this function. 
 
 
Figure 3-15. Gateway Trunk setting 
 
IP 
Destination IP Address is the IP address of the destination 
Gateway that owns this phone number. 
Port 
Port is port of the destination Gateway use. (Default is 5060) 
Table 3-12. Gateway Trunk setting description 
 
 
Trunk Group 
Trunk Group is defines the leading digit of the call out dialing number through SIP / FXO / Gateway 
Trunks of the same type between two given points. The IP PBX will in according to the leading digit to 
determine to use which SIP or Gateway Trunks for outgoing route. 
 
Figure 3-16. Trunk Group setting - 1 
 
Press “more” to show the Service Provider Number under the group. 
 
24