NewAir Kegerator AK-200 Benutzerhandbuch

Seite von 17
refrigerator.
3.  Sit tower down onto opening and turn counter clockwise to lock.
Install Guardrail
1.  Place guardrail (10) over rubber inserts on refrigerator cabinet and push down to 
secure.
Connecting regulator and coupler (Illustrations on page 9)
1.  Make sure regulator valve and CO  tank valve are off by turning clockwise.
2.  Connect regulator (7) to CO  tank (9). Use open wrench included to tighten.
3.  Connect air hose (20) end with green nut to regulator (7).
4.  Insert black CO  rubber washer (4) in opening at back end of coupler (1) before 
connecting air hose (20). Connect other end of air hose (20) to opening at back end 
of coupler (1).
5.
Insert  back  flow  stopper  (2),  round  end  first,  into  top  opening  of  coupler  (1). 
Insert  rubber  washer  (3)  into  wing  nut  at  end  of  beer  line.  Screw  wing  nut  onto  top 
opening of coupler.
Installing Coupler
1.  Make sure black handle on coupler (1) is in the UP position.
2.  Insert coupler (1) into keg and turn clockwise to lock.
3.    Pull  and  hold  black  handle  on  coupler  (1)  up  and  bring  lever  down  to  lock  into 
place.
Regulating Keg
1.  Turn CO  tank valve counter clockwise to open.
2.  Turn blue regulator valve ¼ - ½ turn clockwise.
3.  Within one minute, beer should begin to flow through the beer line.
*  If  beer  is  flowing  too  slowly,  turn  blue  regulator  valve  counterclockwise  until  you 
receive the desired flow.
** If too much foam dispenses, turn off all valves, pull pin on the side of the coupler 
(1) to release the pressure. Wait 30 minutes and repeat steps 1-3 under 'regulating 
keg.
14
QUICK ASSEMBLY INSTRUCTIONS
2
2
2
2