NEC 2400 PX Benutzerhandbuch
NEAX2400 IPX Feature Programming Manual
Page 744
NDA-24297, Issue 1
T-5
TIE Line Connection With Pad Control
Programming (cont’d)
T:
Tandem Connection
ICRT:
Incoming Route Number
OGRT:
Outgoing Route Number
SFC:
Service Feature Class
[Not Used]
IC PAD:
Incoming PAD Data (1-15)
OG PAD:
Outgoing PAD Data (1-15)
RT:
Route Number
[Not Used]
PAD DATA:
TLT (4W E&M)
TLT (4W E&M)
DTI
0-8dB Pad On
0-8dB Pad On
1-2dB Pad On
1-2dB Pad On
2-4dB Pad On
2-4dB Pad On
3-6dB Pad On
3-6dB Pad On
4-8dB Pad On
4-8dB Pad On
15-PAD OFF
7-PAD OFF
FCCS Programming
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
STEP 1:
ARTDN
- Assign the TIE Line routes as shown below:
BOTHWAY LINES:
RT: 1
1-OSGS
1-OSGS
:2
2-ONSG
:3
3-ISGS
:2
4-INSG
:3
5-TF
:3
6-TCL
:4
7-L/T
:1
8-RLP
:2
15-LSG
:5
Pad control is programmed in CDN 30:Pad. For DTI circuit cards, assign data “7”, otherwise assign
data “0”.
data “0”.
STEP 2:
APADN
- Assign the Pad data required for the Tandem connection. Assign the following:
KIND:
Kind of Connection
T:
Tandem Connection
ICRT:
Incoming Route Number
OGRT:
Outgoing Route Number
SFC:
Service Feature Class
[Not Used]
IC PAD:
Incoming PAD Data (1-15)
OG PAD:
Outgoing PAD Data (1-15)
RT:
Route Number
[Not Used]
PAD DATA:
TLT (4W E&M)
TLT (4W E&M)
DTI
0-8dB Pad On
0-8dB Pad On
1-2dB Pad On
1-2dB Pad On
2-4dB Pad On
2-4dB Pad On
3-6dB Pad On
3-6dB Pad On
4-8dB Pad On
4-8dB Pad On
15-PAD OFF
7-PAD OFF