NEC 2400 PX Benutzerhandbuch

Seite von 1089
NEAX2400 IPX Feature Programming Manual
Page 744
NDA-24297, Issue 1
T-5
TIE Line Connection With Pad Control
Programming (cont’d)
T:
Tandem Connection
ICRT:
Incoming Route Number
OGRT:
Outgoing Route Number
SFC:
Service Feature Class
[Not Used]
IC PAD:
Incoming PAD Data (1-15)
OG PAD:
Outgoing PAD Data (1-15)
RT:
Route Number
[Not Used]
PAD DATA:
TLT (4W E&M)
DTI
0-8dB Pad On
1-2dB Pad On
1-2dB Pad On
2-4dB Pad On
2-4dB Pad On
3-6dB Pad On
3-6dB Pad On
4-8dB Pad On
4-8dB Pad On
15-PAD OFF
7-PAD OFF
FCCS Programming 
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
STEP 1:
ARTDN
- Assign the TIE Line routes as shown below:
BOTHWAY LINES:
RT: 1
1-OSGS
:2
2-ONSG
:3
3-ISGS
:2
4-INSG
:3
5-TF
:3
6-TCL
:4
7-L/T
:1
8-RLP
:2
15-LSG
:5
Pad control is programmed in CDN 30:Pad. For DTI circuit cards, assign data “7”, otherwise assign
data “0”.
STEP 2:
APADN
- Assign the Pad data required for the Tandem connection. Assign the following:
KIND:
Kind of Connection
T:
Tandem Connection
ICRT:
Incoming Route Number
OGRT:
Outgoing Route Number
SFC:
Service Feature Class
[Not Used]
IC PAD:
Incoming PAD Data (1-15)
OG PAD:
Outgoing PAD Data (1-15)
RT:
Route Number
[Not Used]
PAD DATA:
TLT (4W E&M)
DTI
0-8dB Pad On
1-2dB Pad On
1-2dB Pad On
2-4dB Pad On
2-4dB Pad On
3-6dB Pad On
3-6dB Pad On
4-8dB Pad On
4-8dB Pad On
15-PAD OFF
7-PAD OFF