Chapter 6
Interactive Control Utility
6-10
www.natinst.com
Status Word
In the Interactive Control utility, all NI-488.2 calls (except 
ibfind
 and 
ibdev
) return the status word 
ibsta
 in two forms: a hex value in square 
brackets and a list of mnemonics in parentheses. In the following example, 
the status word is on the second line, showing that the write operation 
completed successfully: 
ud0: ibwrt "*IDN?"
[0100] (cmpl)
count: 5
ud0:
For more information about 
ibsta
, refer to Chapter 3, 
Error Information
If an NI-488.2 call completes with an error, the Interactive Control utility 
displays the relevant error mnemonic. In the following example, an error 
condition EBUS has occurred during a data transfer:
ud0: ibwrt "*IDN?"
[8100] (err cmpl)
error: EBUS
count: 1
ud0:
+
Turn ON display.
n * function
Execute function 
n
 times where 
function
 represents the correct Interactive 
Control function syntax.
n * !
Execute previous function 
n
 times.
$ filename
Execute indirect file where 
filename
 is the pathname of a file that contains 
Interactive Control functions to be executed.
buffer option
Set type of display used for buffers. Valid options are 
full
brief
ascii
and 
off
. Default is 
full
.
q
Exit or quit.
Table 6-4.  Auxiliary Functions in Interactive Control (Continued)
Function
Description