Juniper Networks T1600 Benutzerhandbuch

Seite von 56
T1600 Routing Node Environmental Specifications
Table 5 on page 44 specifies the environmental specifications required for normal
T1600 routing node operation.
Table 5: T1600 Routing Node Environmental Specifications
Value
Description
No performance degradation to 10,000 ft (3048 m)
Altitude
Normal operation ensured in relative humidity range of 5% to
90%, noncondensing
Relative humidity
Normal operation ensured in temperature range of 32°F (0°C) to
104°F (40°C)
Nonoperating storage temperature in shipping crate: –40°F (–40°C)
to 158°F (70°C)
Temperature
Designed to meet Telcordia Technologies Zone 4 earthquake
requirements
Seismic
28,500 BTU/hour est (8350 W)
NOTE: These specifications are estimates and subject to change.
Maximum thermal output
T1600 Routing Node DC Power Specifications
This section contains specifications for the power system, power supply, and DC
power cables.
Power System Electrical Specifications
Table 6 on page 45 lists the power system electrical specifications.
44
T1600 Routing Node Upgrade Guide