Juniper Networks T1600 Benutzerhandbuch

Seite von 56
NOTE: These components must be installed before you can install a T1600-FPC in
the T1600 routing node.
Power Supplies
Two redundant, load-sharing DC power supplies are located at the lower rear of the
chassis in slots 
PEM0
 and 
PEM1
 (top to bottom). For power specifications for the
Three-Input 240-A Power Supplies
Each three-input 240-A power supply weighs approximately 25 lb. (11.3 kg) and
consists of three inputs, three 80-A circuit breakers, a fan, and LEDs to monitor the
status of the power supply. Figure 3 on page 6 shows the three-input 240-A power
supply.
Figure 3: Three-Input 240-A Power Supply
Three-Input 240-A Power Supply Inputs
The three-input 240-A DC power supply inputs are labeled 
INPUT 0
INPUT 1
, and
INPUT 2
, from top to bottom. Each input consists of –48 VDC and return—each with
its own 80-A circuit breaker. The input mode switch on the faceplate allows you to
set the DC power supply to either two-input or three-input mode mode. Three-input
mode is required for the T1600 routing node. Two-input mode is not currently
supported.
Table 1 on page 7 describes which components are powered by each input.
6
T1600 Upgrade Kit
T1600 Routing Node Upgrade Guide