Jotul GZ 550 DV II Benutzerhandbuch

Seite von 32
4
Specifications
Input Rates
Natural Gas
28,000 BTU/hr. maximum input
16,000 BTU/hr. minimum input
Propane
28,000 BTU/hr. maximum input
15,500 BTU/hr. minimum input
Inlet Pressure:
          MIN
MAX
Natural Gas:   5.0 WC  (1.24 kPa)
   11.0 WC  (2.74 kPa)
Propane:       12.0 WC  (2.98 kPa)           14.9.0 WC  (3.71 kPa)
Manifold Pressure:
       MIN
MAX
Natural Gas:   1.2 WC (.29 kPa)
  3.8 WC  (.94 kPa)
Propane:         2.9 WC (.72 kPa)              11.0 WC  (2.74 kPa)
Jøtul GZ 550 DV II Acadia
Direct Vent Gas Fireplace
Manufactured and Distributed by:
Jøtul A.S.A.
Fredrikstad, Norway
Jøtul North America
Portland, Maine
THIS FIREPLACE IS SHIPPED AS A
N
N
N
N
NA
A
A
A
ATURAL GAS 
TURAL GAS 
TURAL GAS 
TURAL GAS 
TURAL GAS FIREPLACE ONLY.  IF
USE WITH PROPANE IS DESIRED,
THE FIREPLACE MUST BE CON-
VERTED TO USE WITH PROPANE.
FOR YOUR CONVENIENCE THIS
FIREPLACE IS SHIPPED WITH A
PROPANE CONVERSION KIT.
Test Standards
This appliance complies with
National Safety standards
and is tested and listed by
Intertek Testing Services of
Middleton, Wisconsin to ANSI
Z21.88-2002•CSA 2.33-M02
and CAN/CGA 2.17--M91,
CSA P.4.-01.2  for Canada.
DO NOT ATTEMPT TO ALTER OR MODIFY THE CON-
STRUCTION OF THE APPLIANCE OR ITS COMPONENTS.
ANY MODIFICATION OR ALTERATION WILL VOID THE
WARRANTY, CERTIFICATION AND LISTING OF THIS
APPLIANCE.
www.nficertified.org
To ensure your confidence, we recommend
that whenever possible, our products be
installed and serviced by professionals who
are certified by the National Fireplace
Institute (NFI) or, in Canada, by Wood Energy
Technical Training (WETT).
We at Jøtul North America are dedicated to
manufacturing the finest quality hearth
products you can be assured will give you
many years of safe, dependable service.
THIS HEATER MUST BE INSTALLED AND
MAINTAINED BY A QUALIFIED SERVICE
AGENCY.
IN THE COMMENWEALTH OF
MASSACHUSETTS, THIS PRODUCT
MUST BE INSTALLED BY A LICENSED
PLUMBER OR GAS-FITTER.
DO NOT ATTEMPT TO ALTER OR
MODIFY THE CONSTRUCTION OF THIS
APPLIANCE OR ITS COMPONENTS. ANY
MODIFICATION OR ALTERATION WILL
VOID THE WARRANTY, CERTIFICATION
AND LISTING OF THIS APPLIANCE.