MPI Technologies FCX Benutzerhandbuch

Seite von 24

,1752'8&7,21
  352'8&767$1'$5'5$7,1*6
Ratings for Model FCX are provided in the following
table:
Ratings are for the boiler when connected to stan-
dard option coaxial flue system components.
  ',$0(7(52)3,3(&211(&7,216
3HUIRUPDQFH3DUDPHWHU
8QLWV
3URGXFW5DWLQJ
Rated Output
BTUH
76,000
Rated Input
BTUH
81,250
Combustion Chamber Length
Inches
8.98
Combustion Chamber Diameter
Inches
11.5
Combustion Chamber Volume
Cu. Inches
915
Combustion Prod. Circuit Volume
Cu. Inches
3051
Flue Pressure Drop
Inches H2O
0.10
Maximum Heating Service Pressure
Psig
43.5
Max Heating circuit water temperature
Deg. F
176
Water Overheating Safety Thermostat Setting
Deg. F
230
Combustion Prod. Overheating Safety Thermostat Setting
Deg. F
248
Heating Circuit Water Capacity
Gallons
4.23
Primary Water Flow Rate (60/80 deg. C)
Gal/hr
254
Water Pressure Drop (at nominal flow rate)
MCE
1.4
Power Absorbed (with burner, without circulator)
KW
0.22
Packaged Weight 
Lb.
267
Electrical Power Supply
115 volts, single phase, 60 Hz
Full Load Current
3.0 Amps FLA
Max Fuse/ Circuit Breaker Size
15 Amps
&RQQHFWLRQ
'LDPHWHU
8QLWV
Combustion Products 
3.15 / 4.92
Inch
Water Heating Supply/Return
1
Inch
Domestic Hot Water or Second Heating Circuit
1
Inch
Condensate Drain
1 -1/2
Inch
Heating Water Drain
½
Inch
Air Bleed
3/8
Inch
Safety pressure relief valve
3/4
inch