IV.  MAINTENANCE - EVERY 6 MONTHS
A.
Check that the oven is cool and the power is disconnected, as
described in the warning at the beginning of this Section.
B.
Check  for  excessive  wear  on  the  conveyor  drive  motor
brushes.    The  brushes  should  be  replaced  if  they  have
worn to less than 1/4" (6mm) in length.  Be sure to replace
the  brushes  in  exactly  the  same  position.
C.
For gas ovens, inspect and clean the burner nozzle and the
spark  electrode  assembly.
D.
Check  the  conveyor  drive  shaft  bushings  and  spacers.
Replace the components if they are worn.
E.
Blower Belt
1.
Remove  the  six  screws  shown  in  Figure  4-7.    Then,
remove the rear panel from the oven.
2.
Check the blower belt for the proper 1/4" (6mm) deflec-
tion at the center, and for cracking or excessive wear.
See  Figure  4-7.    Overtightening  the  belt  will  cause
premature bearing failure and possible vibrations.  A
loose  belt  may  also  cause  vibrations.
3.
If necessary, adjust the tension of the belt by loosening
the four motor mounting bolts.  Reposition the motor
as neccessary until the correct 1/4" (6mm) deflection
is reached, then tighten the bolts.
F.
Lubricating the Blower Fan Bearings
1.
Use  a  grease  gun  to  lubricate  the  main  blower  fan
shaft  bearings,  as  shown  in  Figure  4-7.
When  lubricating  the  bearings:
• Use a high-quality NLGI #2, lithium soap grease with
petroleum oil, such as Middleby P/N 17110-0015.
• Add the grease slowly until a small bead of grease
is present at the seals. AVOID OVERGREASING.
Excessive greasing may cause harm to the bearing.
2.
Manually turn the blower shaft by pulling on the belt to
purge the grease.  Wipe off any excess grease.
3.
Replace the rear panel onto the oven.
Remove  six  (6)
screws  to  remove
rear panel
Blower belt
Bearings
(2 total)
Blower motor
Loosen four (4) screws to adjust
motor position and belt tension
Figure 4-7 - Rear panel access
Grease  fitting
(1 per
bearing)