LaCie FIREWIRE 800/400 Benutzerhandbuch

Seite von 59
LaCie Biggest Quadra
User Manual
page 
Setting Up the Biggest Quadra
This  is  the  default  setting  of  the  LaCie  Biggest 
Quadra.  Follow these steps to set the RAID level at 
RAID 5.
Power off the LaCie Biggest Quadra.
Move switch 1 and 2 of the RAID Level Switch Se-
lectors to the 
OFF
 position.
1.
2.
4.1.1. RAID 5
CAUTION:
  In  a  RAID  5  array,  in  the  event 
that a disk needs to be replaced, always replace the 
failed disk with the LaCie Biggest Quadra’s power 
on. Do not turn the LaCie Biggest Quadra’s power 
off; doing so may lead to the loss of the data on 
the array.
ImpOrTANT  INfO:
  In  a  RAID  5  +  Hot 
Spare array, the disk in the top drive bay is desig-
nated as the Hot Spare (the default setting), and 
the  Disk  Status  Indicator  will  light  in  amber  to 
indicate this configuration.
Power off the LaCie Biggest Quadra.
Move switch 1 of the RAID Level Switch Selectors 
to the 
OFF
 position. Move switch 2 of the RAID 
Level Switch Selectors to the 
ON
 position.
1.
2.
4.1.2. RAID 5 + Hot Spare
TeChNICAl  NOTe:
 In the initial configura-
tion of a RAID 5 + Hot Spare array, the top drive 
bay (Drive Bay 1) is the default Hot Spare (the Disk 
Status Indicator will be amber). In the event that a 
disk fails, the Hot Spare position will change.
For example, if the disk in Drive Bay 3 fails, then 
the Hot Spare disk in Drive Bay 1 will be re-built 
and  will  no  longer  be  the  Hot  Spare.  Instead, 
when you place a new disk in Drive Bay 3, it will 
become the new Hot Spare, and will be indicated 
by the amber Disk Status Indicator.
Fig. 4.1.1
Fig. 4.1.2