Connect two wires from the 
wall to the BLACK wires from 
the switch timer, using the twist 
connectors provided. 
If the old switch had a ground 
wire (normally connected to a 
green hex-head screw), fasten it 
securely to the metal box or timer metal bracket.
Make sure all twist connectors are tight.
Tuck wires into wall box leaving room for the device.
Using 2 flat-head screws provided, mount the switch timer 
into the wall box.
Position the wall plate over the switch timer, 
making sure the upper screw hole of the wall 
plate is over the RED indicator light.
Install the control panel over the wall plate as 
follows:
Position the clear plastic lens into the up-
per screw hole in the wall plate.
Make sure the post next to the knob shaft 
is properly aligned with the control lever 
hole in the control panel.
Install the dome-head screw in the bottom 
hole of the control panel, on through the 
bottom hole of the switch plate. Tighten 
snugly but DO NOT OVERTIGHTEN.
Install the white plug over the dome-head 
screw.
Press the dial onto the switch timer’s shaft. 
Align the flat side of the shaft with the flat side 
within the dial.
Turn power back on at the service panel.
5.
6.
7.
8.
9.
10.
11.
a.
b.
c.
d.
12.
13.
Indoor Wall Switch Timer
The EJ351 Switch Timer replaces a standard toggle switch. 
Installation requires the following tools:
Flat-blade screwdriver
Phillips-head screwdriver
Turn off power at the service panel by REMOVING FUSE or 
TURNING THE CIRCUIT BREAKER OFF.
Remove the switchplate and existing wall switch.
Remove the dial and control panel from the switch timer. 
Gently and firmly pull straight out to remove.
Trim building wires to 7/16” as shown.

1.
2.
3.
4.
500W maximum, 40W minimum (incandescent)
NOTE: Derate to 400W maximum when 2 or more timers are 
installed in the same wall box.
120 VAC, 60 Hz
30 minute minimum ON/OFF period
24-hour repeat cycle
Up to 48 daily operation events (24 ON, 24 OFF)
Random Variability: For “lived in” look, ON/OFF times vary at 
least 7 minutes from the set time  and at least 15 minutes from 
the previous day.
Power Failure Memory Protection: Depending on conditions at 
time of power failure, will retain settings up to 15 minutes.
Operate at Room Temperature: 32°F (0°C) to 104°F (40°C)




MODEL EJ351
Installing the Switch Timer
Specifications
BLACK
BLACK
RED
Indicator
Light
7/16”
Electrical shock hazard. Risk of injury or death. Remove electrical power at 
service panel before installing.
Risk of fire. Do not use timer to control devices that could have dangerous 
consequences due to inaccurate timing such as sun lamps, sauna, heaters, 
crock pots, etc.
          WARNING
Follow local electrical codes during installation.
Do not use with PAR or “R”-type outdoor flood lamps larger than 150 watts.
Use ONLY with incandescent lights. Do not use with compact fluorescent 
lamps (CFLs), starter or other electronic ballasts, mercury vapor lights, ap-
pliances, radios TVs, stereos, etc.
Do not use in combination with separate dimmers or photoelectric switches. 
In rare cases, may cause radio or TV interference which can be resolved by 
adjusting the antenna, moving the receiver, or plugging the receiver into a 
different AC outlet. 



NOTICE
Use this procedure to manually program ON/OFF settings.
Move the control lever to the OFF-CLEAR position for about 
20 seconds. The red indicator light will go off and any previ-
ous time settings will be cleared from memory.
Move the control lever to the ON position. The Red indicator 
light will start flashing.
Rotate the time dial clockwise at least one click, stopping at 
the half hour nearest to the present time.
NOTE: During programming, be careful not to press the 
dial while turning it. If you press the dial, you will ac-
cidentally set a wrong time.
Press the dial once to set the present time. The Red indicator 
light will go off.
Rotate the time dial clockwise to the first desired ON time. 
The Red light will pulse momentarily with each click.
Press the dial once to enter the ON time. The light controlled 
by the switch timer will turn ON.
Rotate the time dial clockwise to the desired OFF time. 
Press the dial once to enter the OFF time. The light controlled 
by the switch timer will turn OFF.
Repeat Steps 5-8 for each additional ON/OFF setting.
Continue to rotate the time dial until the Red indicator light 
comes ON and stays ON, indicating that the switch timer is in 
AUTOMATIC mode.
1.
2.
3.
1.
2.
3.
4.
5.
6.
7.
Programming Using the RAPID Method
Red
Indicator
Light
Control
Lever
Push-Button
Time Dial
Control
Panel
Plastic
Screw
Cover
INCLUDED FOR INSTALLATION:
Flat
Head
Screws
(2)
Dome
Head
Screw
(1)
Twist 
Connectors
 (2)
Plastic
Screw
Cover
(1)
RED Indicator Light
Clear
Plastic
Lens
Align with 
Hole in
Control Panel
Installation and User Instructions