IBM Partner Pavilion Vitrual Switch Extension BMD00082 Benutzerhandbuch

Seite von 166
SmartConnect User’s Guide
110  
„
  Chapter 9: Switch Policies
BMD00082, February 2009
ACL Metering Settings
The following table describes the ACL metering configuration controls: 
ACL Remark Control
The following table describes the ACL remarking configuration controls: 
See also:
„
„
Table 9-5  
ACL Metering Configuration Fields
Field
Description
Committed rate
Configures the committed rate, in Kilobits per second. The committed 
rate must be a multiple of 64.
Maximum burst size
Configures the maximum burst size, in Kilobits. Enter one of the fol-
lowing values for mbsize: 32, 64, 128, 256, 512, 1024, 2048, 4096
Set out-of-profile Drop or 
Pass
Configures the ACL Meter to either drop or pass out-of-profile traffic.
Enable
Enables or disables the ACL meter.
Table 9-6  
ACL Remarking Configuration Fields
Field
Description
Set in-profile update DSCP 
enable
Enables or disables DiffServ Code Point (DSCP) updates for In-Profile 
packets.
Set in-profile update DSCP
Sets the DSCP of In-Profile packets to the selected value.
Set out-of-profile update 
DSCP enable
Enables or disables DSCP updates for Out-of-Profile packets.
Set out-of-profile update 
DSCP
Sets the DSCP of Out-of-Profile packets to the selected value.