IBM Partner Pavilion DS4100 Benutzerhandbuch

Seite von 180
b.
   
Pull
 
the
 
handle
 
on
 
the
 
tray
 
out
 
so
 
that
 
it
 
is
 
in
 
the
 
open
 
position,
 
as
 
shown
 
in
 
 
Tray handle
Tray latch
f10ug049
  
 
 
c.
   
Slide
 
the
 
drive
 
CRU
 
into
 
the
 
empty
 
bay
 
until
 
the
 
hinge
 
of
 
the
 
tray
 
handle
 
latches
 
beneath
 
the
 
storage
 
server
 
bezel.
 
d.
   
Push
 
the
 
tray
 
handle
 
down
 
until
 
it
 
latches
 
into
 
place.
Replacing
 
hot-swap
 
hard
 
disk
 
drives
 
Drive
 
problems
 
include
 
any
 
malfunctions
 
that
 
delay,
 
interrupt,
 
or
 
prevent
 
successful
 
I/O
 
activity
 
between
 
the
 
hosts
 
and
 
the
 
hard
 
disk
 
drives
 
in
 
the
 
storage
 
server.
 
This
 
includes
 
transmission
 
problems
 
between
 
the
 
host
 
controllers,
 
the
 
RAID
 
controllers,
 
and
 
the
 
drives.
 
This
 
section
 
explains
 
how
 
to
 
replace
 
a
 
failed
 
hard
 
disk
 
drive.
 
Note:
  
If
 
you
 
want
 
to
 
remove
 
a
 
hard
 
disk
 
drive
 
that
 
is
 
not
 
in
 
a
 
failed
 
or
 
bypass
 
state,
 
always
 
use
 
the
 
DS4000
 
Storage
 
Manager
 
client
 
program
 
either
 
to
 
place
 
the
 
drive
 
in
 
a
 
failed
 
state
 
or
 
to
 
place
 
the
 
array
 
that
 
is
 
associated
 
with
 
the
 
drive
 
(or
 
drives)
 
in
 
an
 
offline
 
state
 
before
 
you
 
remove
 
the
 
drive
 
from
 
the
 
enclosure.
 
Attention:
  
Failure
 
to
 
replace
 
the
 
hard
 
disk
 
drives
 
in
 
their
 
correct
 
bays
 
might
 
result
 
in
 
loss
 
of
 
data.
 
If
 
you
 
are
 
replacing
 
a
 
hard
 
disk
 
drive
 
that
 
is
 
part
 
of
 
a
 
configured
 
array
 
and
 
logical
 
drive,
 
ensure
 
that
 
you
 
install
 
the
 
replacement
 
hard
 
disk
 
drive
 
in
 
the
 
correct
 
bay.
 
Check
 
the
 
hardware
 
and
 
software
 
documentation
 
that
 
is
 
provided
 
with
 
your
 
DS4000
 
storage
 
server
 
to
 
see
 
if
 
there
 
are
 
restrictions
 
regarding
 
hard
 
disk
 
drive
 
configurations.
 
Complete
 
the
 
following
 
steps
 
to
 
replace
 
a
 
hot-swap
 
hard
 
disk
 
drive:
 
1.
   
Determine
 
the
 
location
 
of
 
the
 
drive
 
that
 
you
 
want
 
to
 
remove.
 
 
Attention:
  
Never
 
hot-swap
 
a
 
drive
 
CRU
 
when
 
its
 
green
 
Activity
 
LED
 
is
 
flashing.
 
Hot-swap
 
a
 
drive
 
CRU
 
only
 
when
 
its
 
amber
 
Fault
 
LED
 
is
 
on
 
and
 
not
 
flashing
 
or
 
when
 
the
 
drive
 
is
 
inactive
 
with
 
the
 
green
 
Activity
 
LED
 
on
 
and
 
not
 
flashing.
 
If
 
the
 
drive
 
is
 
not
 
in
 
a
 
failed
 
state
 
(as
 
indicated
 
by
 
its
 
lit
 
amber
 
LED),
 
manually
 
fail
 
the
 
drive
 
using
 
the
 
Storage
 
Management
 
client
 
before
 
attempting
 
to
 
remove
 
it
 
from
 
the
 
drive
 
slot.
 
2.
   
Remove
 
the
 
drive
 
CRU:
 
Figure
 
63.
 
Drive
 
CRU
 
handle
 
 
82
 
IBM
 
TotalStorage
 
DS4100
 
Storage
 
Server:
 
Installation,
 
User’s,
 
and
 
Maintenance
 