IBM Partner Pavilion DS4100 Benutzerhandbuch

Seite von 180
power
 
to
 
the
 
storage
 
server.
 
Go
 
to
 
and
 
follow
 
the
 
procedure
 
described
 
there
 
before
 
proceeding
 
with
 
the
 
following
 
step.
 
9.
   
Make
 
sure
 
that
 
the
 
green
 
Power
 
LED
 
on
 
the
 
new
 
power-supply
 
CRU
 
is
 
on
 
and
 
the
 
amber
 
Fault
 
LED
 
is
 
off.
 
v
   
If
 
the
 
Power
 
LED
 
is
 
off,
 
the
 
power-supply
 
CRU
 
might
 
not
 
be
 
installed
 
correctly.
 
Remove
 
it
 
and
 
then
 
reinstall
 
it.
 
v
   
If
 
the
 
Fault
 
LED
 
is
 
on
 
or
 
the
 
Power
 
LED
 
stays
 
off,
 
test
 
the
 
power
 
source
 
to
 
verify
 
that
 
the
 
outlet
 
is
 
working
 
properly.
 
For
 
more
 
information
 
about
 
the
 
LEDs,
 
see
 
Working
 
with
 
RAID
 
controllers
 
The
 
DS4100
 
base
 
storage
 
server
 
operates
 
with
 
two
 
RAID
 
controllers
 
that
 
can
 
be
 
hot-swapped.
 
The
 
DS4100
 
single-controller
 
storage
 
server
 
has
 
only
 
one
 
RAID
 
controller.
 
If
 
you
 
are
 
replacing
 
a
 
failed
 
RAID
 
controller
 
in
 
the
 
DS4100
 
single-controller
 
storage
 
server,
 
you
 
do
 
not
 
need
 
to
 
power
 
down
 
the
 
DS4100
 
before
 
replacing
 
the
 
RAID
 
controller.
 
If
 
you
 
are
 
replacing
 
a
 
functioning
 
(non-failed)
 
RAID
 
controller
 
in
 
the
 
DS4100
 
single-controller
 
storage
 
server,
 
do
 
not
 
remove
 
or
 
replace
 
the
 
RAID
 
controller
 
in
 
the
 
DS4100
 
single-controller
 
storage
 
server
 
without
 
first
 
stopping
 
the
 
host
 
applications,
 
unmounting
 
the
 
logical
 
drives
 
from
 
the
 
host
 
server,
 
and
 
powering
 
down
 
the
 
storage
 
subsystem.
 
 
Attention:
  
Before
 
you
 
replace
 
a
 
RAID
 
controller,
 
verify
 
that
 
the
 
replacement
 
RAID
 
controller
 
part
 
number
 
match
 
the
 
part
 
number
 
of
 
the
 
RAID
 
controller
 
be
 
replaced.
 
Each
 
RAID
 
controller
 
fits
 
into
 
the
 
back
 
of
 
the
 
storage
 
server
 
and
 
has
 
the
 
following
 
components:
 
v
   
Battery
 
v
   
Cache
 
memory
 
v
   
Two
 
host
 
ports
 
and
 
one
 
expansion
 
port
Note:
  
The
 
expansion
 
port
 
is
 
inactive
 
in
 
the
 
DS4100
 
single-controller
 
storage
 
server.
 
v
   
One
 
Ethernet
 
port
 
v
   
One
 
serial
 
port
Each
 
RAID
 
controller
 
has
 
a
 
unique
 
hardware
 
Ethernet
 
address,
 
which
 
is
 
printed
 
on
 
a
 
label
 
on
 
the
 
front.
 
There
 
is
 
also
 
a
 
label
 
giving
 
the
 
cache
 
battery
 
manufacturing
 
and
 
installation
 
dates
 
on
 
the
 
top
 
of
 
the
 
controller
 
unit.
 
shows
 
the
 
location
 
of
 
these
 
items.
 
Important:
 
Please
 
read
 
the
 
following
 
information
 
before
 
replacing
 
a
 
RAID
 
controller.
 
v
   
The
 
cache
 
battery
 
is
 
not
 
included
 
with
 
the
 
controller
 
CRU.
 
v
   
To
 
provide
 
full
 
functionality
 
in
 
a
 
DS4100
 
base
 
storage
 
server,
 
the
 
two
 
controllers
 
must
 
have
 
the
 
same
 
memory
 
capacity.
 
To
 
ensure
 
that
 
you
 
replace
 
the
 
failed
 
controller
 
with
 
an
 
appropriate
 
replacement
 
controller,
 
verify
 
that
 
the
 
FRU
 
number
 
of
 
the
 
replacement
 
controller
 
matches
 
the
 
FRU
 
number
 
of
 
the
 
failed
 
controller.
 
There
 
are
 
no
 
protection
 
mechanisms
 
to
 
block
 
out
 
an
 
incorrect
 
CRU
 
from
 
being
 
 
 
94
 
IBM
 
TotalStorage
 
DS4100
 
Storage
 
Server:
 
Installation,
 
User’s,
 
and
 
Maintenance
 
Guide