IBM Partner Pavilion DS4100 Benutzerhandbuch

Seite von 180
10.
   
Use
 
the
 
SMW
 
to
 
download
 
firmware
 
to
 
the
 
new
 
controller
 
to
 
match
 
the
 
version
 
number
 
shown
 
in
 
your
 
storage
 
subsystem
 
profile.
 
(Refer
 
to
 
your
 
printout.)
 
After
 
15-20
 
minutes,
 
the
 
SMW
 
reports
 
a
 
download
 
failure.
 
Click
 
OK
 
to
 
ignore
 
the
 
error
 
warning
 
and
 
instructions
 
and
 
proceed
 
with
 
the
 
following
 
step.
 
11.
   
Use
 
the
 
EMW
 
to
 
remove
 
the
 
RAID
 
controller
 
from
 
the
 
management
 
domain,
 
and
 
again
 
add
 
the
 
new
 
controller
 
using
 
the
 
IP
 
address
 
assigned
 
to
 
the
 
new
 
controller
 
by
 
the
 
IP
 
server.
 
12.
   
View
 
the
 
storage
 
subsystem
 
profile
 
and
 
confirm
 
that
 
the
 
NVSRAM
 
and
 
controller
 
firmware
 
versions
 
match
 
the
 
versions
 
shown
 
in
 
your
 
storage
 
subsystem
 
profile
 
printout.
 
13.
   
Use
 
the
 
EMW
 
to
 
remove
 
the
 
RAID
 
controller
 
from
 
the
 
management
 
domain.
 
14.
   
Use
 
the
 
procedure
 
described
 
in
 
to
 
power
 
off
 
the
 
storage
 
server.
 
15.
   
Reinstall
 
each
 
drive
 
in
 
the
 
slot
 
from
 
which
 
it
 
was
 
removed.
 
16.
   
Power
 
on
 
the
 
storage
 
server,
 
using
 
the
 
procedure
 
described
 
in
 
17.
   
Use
 
the
 
EMW
 
to
 
add
 
the
 
RAID
 
controller
 
back
 
into
 
the
 
management
 
domain
 
using
 
the
 
original
 
IP
 
address
 
(refer
 
to
 
your
 
printout).
 
18.
   
Verify
 
that
 
the
 
RAID
 
controller
 
is
 
accessible.
 
19.
   
Continue
 
with
 
in
 
the
 
RAID
 
controller
 
replacement
 
procedure.
Replacing
 
the
 
battery
 
in
 
the
 
RAID
 
controller
 
Each
 
RAID
 
controller
 
contains
 
a
 
rechargeable
 
battery
 
that
 
maintains
 
the
 
data
 
in
 
the
 
cache
 
memory
 
for
 
three
 
days
 
without
 
power
 
to
 
the
 
unit.
 
Important:
  
If
 
you
 
are
 
replacing
 
the
 
battery
 
in
 
a
 
DS4100
 
single-controller
 
storage
 
server,
 
complete
 
the
 
following
 
steps
 
before
 
beginning
 
the
 
replacement
 
procedure:
 
1.
   
Schedule
 
down
 
time
 
for
 
the
 
battery
 
replacement,
 
because
 
the
 
disk
 
will
 
not
 
be
 
available
 
during
 
the
 
procedure.
 
2.
   
Complete
 
any
 
necessary
 
server
 
preparation
 
tasks.
 
3.
   
Save
 
the
 
configuration
 
storage
 
subsystem
 
profile.
Note:
  
Before
 
any
 
planned
 
system
 
shutdown
 
or
 
after
 
any
 
system
 
additions,
 
removals,
 
or
 
modifications
 
(including
 
logical
 
drive
 
creations,
 
storage
 
partitioning
 
definitions,
 
hardware
 
changes,
 
and
 
so
 
on),
 
save
 
the
 
storage
 
subsystem
 
profile
 
as
 
explained
 
in
 
the
 
DS4000
 
Storage
 
Manager
 
guide
 
for
 
your
 
operating
 
system.
 
Save
 
the
 
profile
 
in
 
a
 
location
 
other
 
than
 
the
 
logical
 
drives
 
created
 
for
 
the
 
DS4100
 
storage
 
server.
 
4.
   
Stop
 
I/O
 
to
 
the
 
storage
 
server.
 
5.
   
Unmount
 
any
 
mapped
 
LUNs
 
from
 
the
 
storage
 
server.
 
6.
   
Power
 
down
 
the
 
DS4100
 
single-controller
 
storage
 
server,
 
as
 
described
 
in
 
Use
 
the
 
following
 
procedure
 
if
 
the
 
DS4000
 
Storage
 
Manager
 
client
 
instructs
 
you
 
to
 
replace
 
the
 
battery
 
because
 
the
 
current
 
battery
 
has
 
failed
 
or
 
is
 
nearing
 
its
 
expiration
 
date.
 
You
 
can
 
also
 
use
 
the
 
DS4000
 
Storage
 
Manager
 
client
 
to
 
check
 
the
 
status
 
of
 
the
 
battery.
 
 
1.
   
Check
 
the
 
DS4000
 
Storage
 
Manager
 
client
 
online
 
help
 
for
 
instructions
 
on
 
battery
 
replacement
 
procedures.
 
If
 
you
 
are
 
using
 
write-cache
 
mirroring,
 
this
 
 
 
Chapter
 
5.
 
Installing
 
and
 
replacing
 
components
 
105