IBM Partner Pavilion DS4100 Benutzerhandbuch

Seite von 180
Installing
 
SFPs
 
and
 
fiber-optic
 
cables
 
Each
 
RAID
 
controller
 
unit
 
has
 
two
 
host
 
ports
 
and
 
one
 
expansion
 
unit
 
port.
 
SFPs
 
are
 
inserted
 
into
 
the
 
ports,
 
and
 
then
 
fibre-channel
 
cables
 
are
 
connected
 
to
 
the
 
SFPs.
 
For
 
information
 
on
 
installing
 
SFPs
 
and
 
fiber-optic
 
cables,
 
see
 
Adding
 
a
 
DS4000
 
EXP100
 
to
 
an
 
existing
 
DS4100
 
configuration
 
(base
 
storage
 
server
 
only)
 
You
 
can
 
add
 
up
 
to
 
seven
 
DS4000
 
EXP100
 
storage
 
expansion
 
units
 
to
 
a
 
DS4100
 
storage
 
server.
 
However,
 
you
 
do
 
not
 
need
 
to
 
configure
 
the
 
DS4100
 
with
 
the
 
maximum
 
number
 
of
 
DS4000
 
EXP100s
 
at
 
the
 
time
 
of
 
initial
 
installation.
 
You
 
can
 
add
 
additional
 
DS4000
 
EXP100s
 
to
 
an
 
existing
 
DS4100
 
configuration
 
(up
 
to
 
the
 
maximum
 
number
 
of
 
DS4000
 
EXP100s
 
supported
 
in
 
a
 
drive
 
loop)
 
as
 
you
 
need
 
more
 
capacity.
 
 
 
Important
 
There
 
might
 
be
 
a
 
requirement
 
for
 
new
 
firmware
 
to
 
support
 
the
 
maximum
 
number
 
of
 
DS4000
 
EXP100s
 
in
 
a
 
drive
 
loop.
 
Always
 
add
 
new
 
DS4000
 
EXP100s
 
when
 
the
 
DS4100
 
is
 
powered
 
on
 
and
 
in
 
optimal
 
state.
 
Do
 
not
 
add
 
new
 
DS4000
 
EXP100s
 
when
 
the
 
DS4100
 
is
 
powered
 
down.
 
Before
 
you
 
cable
 
DS4000
 
EXP100s
 
to
 
a
 
loop,
 
refer
 
to
 
the
 
DS4100
 
Storage
 
Server
 
Fibre
 
Channel
 
Cabling
 
Instructions
 
that
 
come
 
with
 
your
 
storage
 
server
 
for
 
specific
 
instructions.
 
shows
 
the
 
process
 
of
 
adding
 
an
 
additional
 
DS4000
 
EXP100
 
to
 
an
 
existing
 
DS4100
 
storage
 
server
 
configuration.
 
Drive
 
loops
 
A
 
and
 
B
 
form
 
one
 
redundant
 
fibre-channel
 
loop.
 
Note:
  
Always
 
add
 
a
 
new
 
DS4000
 
EXP100
 
to
 
the
 
end
 
of
 
a
 
drive
 
loop.
 
 
 
Chapter
 
5.
 
Installing
 
and
 
replacing
 
components
 
109