IBM Partner Pavilion DS4100 Benutzerhandbuch

Seite von 180
Table
 
17.
 
Symptom-to-FRU
 
index
 
(continued)
 
Problem
 
indicator
 
Component
 
Possible
 
cause
 
Possible
 
solutions
 
The
 
DS4000
 
Storage
 
Manager
 
client
 
Enterprise
 
Management
 
window
 
sees
 
each
 
storage
 
server
 
controller
 
as
 
an
 
independent
 
storage
 
subsystem
 
or
 
a
 
partially
 
managed
 
device.
 
Controller
 
No
 
drives
 
are
 
present
 
in
 
the
 
storage
 
server.
 
Ensure
 
that
 
at
 
least
 
one
 
drive
 
is
 
present
 
in
 
the
 
storage
 
server
 
so
 
that
 
it
 
can
 
be
 
configured
 
properly.
 
One
 
controller
 
was
 
replaced
 
incorrectly.
 
The
 
controller
 
firmware
 
versions
 
probably
 
failed
 
to
 
synchronize
 
correctly.
 
To
 
recover,
 
perform
 
the
 
following
 
steps:
 
1.
   
Remove
 
and
 
reinsert
 
the
 
controller
 
blade.
 
2.
   
Wait
 
5
 
minutes.
 
3.
   
Delete
 
the
 
controller
 
entry
 
with
 
the
 
incorrect
 
firmware
 
version
 
from
 
the
 
DS4000
 
Storage
 
Manager
 
Enterprise
 
Management
 
window.
 
4.
   
Add
 
the
 
controller
 
back
 
to
 
the
 
DS4000
 
Storage
 
Manager
 
Enterprise
 
Management
 
window
 
using
 
the
 
Add
 
Device
 
menu
 
option
 
in
 
the
 
Enterprise
 
Management
 
window.
 
5.
   
If
 
the
 
DS4000
 
Storage
 
Manager
 
client
 
Enterprise
 
Management
 
window
 
still
 
shows
 
each
 
storage
 
server
 
controller
 
as
 
an
 
independent
 
storage
 
subsystem
 
or
 
a
 
partially
 
managed
 
device,
 
repeat
 
this
 
procedure.
 
If
 
the
 
problem
 
still
 
persists,
 
contact
 
IBM
 
support.
  
Note:
  
If
 
you
 
cannot
 
find
 
the
 
problem
 
in
 
the
 
Symptom-to-FRU
 
index,
 
test
 
the
 
entire
 
system.
 
Parts
 
listing
 
and
 
the
 
following
 
table
 
provide
 
a
 
parts
 
listing
 
for
 
the
 
DS4100.
 
 
 
Chapter
 
6.
 
Hardware
 
maintenance
 
115