IBM Partner Pavilion DS4100 Benutzerhandbuch

Seite von 180
one-half
 
of
 
the
 
current
 
load.
 
If
 
there
 
is
 
only
 
one
 
power
 
supply
 
unit,
 
it
 
will
 
handle
 
all
 
of
 
the
 
current
 
load.
 
To
 
ensure
 
maximum
 
protection
 
against
 
power
 
loss
 
due
 
to
 
power
 
supply
 
unit
 
failure
 
or
 
a
 
power
 
circuit
 
tripping,
 
both
 
power
 
supply
 
units
 
must
 
be
 
connected
 
and
 
powered
 
on.
 
See
 
for
 
the
 
DS4100
 
AC
 
power
 
requirements.
 
See
 
for
 
an
 
example
 
of
 
redundant
 
power
 
cabling.
 
Exception:
 
The
 
DS4100
 
single-controller
 
storage
 
server
 
has
 
only
 
one
 
power
 
supply,
 
so
 
it
 
does
 
not
 
support
 
power
 
redundancy.
 
 
 
For
 
details
 
about
 
power
 
requirements,
 
see
 
6.
   
Go
 
to
 
for
 
the
 
initial
 
startup
 
of
 
the
 
storage
 
server.
 
Attention:
  
Before
 
you
 
power
 
on
 
the
 
storage
 
server,
 
any
 
storage
 
expansion
 
units
 
should
 
be
 
completely
 
connected
 
to
 
the
 
storage
 
server.
Installing
 
the
 
DS4000
 
Storage
 
Manager
 
client
 
Refer
 
to
 
the
 
IBM
 
TotalStorage
 
DS4000
 
Storage
 
Manager
 
9.10
 
Installation
 
and
 
Support
 
Guide
 
for
 
the
 
appropriate
 
operating
 
system
 
for
 
instructions
 
on
 
how
 
to
 
install
 
the
 
Storage
 
Manager
 
software.
 
Use
 
that
 
document
 
and
 
the
 
online
 
help
 
to
 
configure
 
the
 
logical
 
drives,
 
partitions,
 
and
 
so
 
on
 
for
 
the
 
RAID
 
controllers.
 
Use
 
your
 
operating
 
AC distribution unit
power cord
Controller power supplies
Drive expansion unit
power supplies
Rack power cable connector
Rack power cable
AC distribution units
f10ug060
  
Figure
 
56.
 
Redundant
 
AC
 
power
 
connections
 
to
 
controllers
 
and
 
drive
 
expansion
 
units
 
 
62
 
IBM
 
TotalStorage
 
DS4100
 
Storage
 
Server:
 
Installation,
 
User’s,
 
and
 
Maintenance
 
Guide